ViewSonic EXES-2000 manual Transfer, Secretary transfer Hurry up, Door remote control 2 circuits

Page 22

LIST OF FUNCTION AVAILABLE FROM EXES-2000 SYSTEM

Classifi- No. cation

1.

2.

3.

4,

5.

6.Call

7.

8.

9.PTT

10.

11.

12.

13.

14.Transfer

15.

16.

17.

18.

19.

Paging

20.

21.

22.

23.Selection

24.

25.

26.

27.

28.

29.

30.

Function

Camp-on-busy

Busy call-back

Mic off

Muster sub relationship

Privacy/Camp-on-privacy

Continuous call tone station (1*)

Handset operated station (2*)

Press-to-talk

Talkback

Press-to-talk control

Personal number call

Conference

Call transfer

Call forwarding

Secretary transfer

Hurry up

Executive (Highest) priority

Station paging call-up (all-call paging + 3 zone paging calls) and its response (3*)

PA paging call-up (all-call paging + 3 zone paging) and its response (3*)

Selected station paging

Emergency all-call paging

PA paging & power remote/3-channel general purpose control

Time-Out of paging call (no limit/20 seconds) Speech message hurry up recording (with/without) 3-channel BGM

Alarm and time signal

Pager calling and response

Door remote control (2 circuits)

Speech message

Tie-line

Selectable functions

Basic (No.24 programming Additional function must be established) functions

Note that × × / Y Y (Example. with/without of Item No. 24) shows either ×× or YY can be adopted.

1* The station having its Privacy switch in the OFF mode can select either a "brief" call tone or "continuous" call tone. (The station without the Privacy switch is the same as one having its Privacy switch in OFF.)

2* With the Privacy switch in the ON position, either the "Privacy tone" or "continuous tone" can be selected. (The handset operated station is always in the same Privacy state as the station whose Privacy switch is set to OFF.

3* Each paging channel can be either station paging or PA paging or combined station and PA paging.

– 21 –

Image 22
Contents EX-200 Contents Before Reading this Hand BookPower Description and featuresExamples of system configuration BGM distribution up to 3 channelsCentral control unit CC-20 Remote control unit RC-20Power transformer unit PU-200 Line modem unit LM-20Installation of equipment Installing and adjusting proceduresSelection of the place to install Installation of the exchange DimensionsInstalling FC-210 extension cabinet Installation of PU-200 power supply unit Wall Base Case For case Switch boxFor plate Exchange Cable installationR51 or R59 390k ohms on the LM unit corresponding to Indoor ExchangeterminalStations boardEstablishment of the LM unit number Connection of equipmentAddition of LM unit Mounting LM unit For the system with up to 16 stationsLM unit wiring Mounting option unit Bl unit Connection of station plug to jackMounting other option units than the Bl unit Bl unit connection Alarm tone, etcBGM equipment Door locking RC unit connectionPTT.C PTT control Radio Station EquipmentMaximum contact capacity 125 VA 125V AC or 30V DC 1A PC unit connectionSerial data output Tl unit connection SM unit number setting Service distance Connection for speaker stationConnection of power source Voltage selectorProcedures of initial set-up and No programming Initial set-up and programming No programmingTransfer PA paging & power remote/3-channel general purpose controlDoor remote control 2 circuits Secretary transfer Hurry upRegistration of each function EX-610/620/630Highest Executive Priority Will be heard Times Be sure to depress Key Steadily Continuous Calling ToneTouch Stations Allowed Access to Paging Stations Allowed Access to Emergency Call Allowed Station NoHandset Station Registration Will be heardHave this Function Times Be sure to depress Key SteadilyStations Allowed Access to Speech Message AllowedDoor Substation Registration Secretary Transfer Release finished?MASTER/SUB Relationship Registration of Stations to Refuse ALL-CALL Paging Registration of Station to Refuse Zone 1 Paging Dial Will be heard TimesRegistration of Stations to Refuse Zone 2 Paging Repeat twice Registration of next allowed stationRegistration of Stations to Refuse Zone 3 Paging Step Method of Speech test Hands-free conversation Performance TestSpeech and Function Tests Speech Test Handset conversationTrouble-shooting at the time of installation Noise is heard from the station Replace stationFunction Table for Stations Door SubstationStation Data Table Station Data Table3 0 6 1 3 5 6 C