ViewSonic EXES-2000 manual Wall Base Case, For case Switch box, For plate

Page 9

4-5 Installation of Stations

To install stations, make connections by using station jack model YC-601 (Wall-mounted type) or YC-603 (Flush-mounted type). Since the length of station cord is 3 meters (9.8 feet), the station jack needs to be mounted within this length.

Station jack YC-601 (Wall-mounted type)

Mount this jack on a wall, pillar or desk. Utilize either knock-out

holes provided on the top and the bottom of the case or a cable

entry hole in the base for connecting the cables to the ex- change.

Station jack YC-603 (Flush-mounted type)

Mount switch box and make piping and wiring arrangements

before the station jack is installed.

Knock-out hole

(provided on the top and bottom)

Screw for base

Base

Cable entry hole

Screw

Case

Plate

Screw

Wall

Base

Case

Screw

Cable entry hole

 

for box

 

Screw

for case

Switch box

Other stations

Please refer to instruction manual of each station.

for plate

– 8 –

Image 9
Contents EX-200 Before Reading this Hand Book ContentsExamples of system configuration Description and featuresPower BGM distribution up to 3 channelsPower transformer unit PU-200 Remote control unit RC-20Central control unit CC-20 Line modem unit LM-20Installing and adjusting procedures Installation of equipmentSelection of the place to install Dimensions Installation of the exchangeInstalling FC-210 extension cabinet Installation of PU-200 power supply unit For case Switch box Wall Base CaseFor plate R51 or R59 390k ohms on the LM unit corresponding to Cable installationExchange Indoor ExchangeterminalStations boardAddition of LM unit Connection of equipmentEstablishment of the LM unit number Mounting LM unit For the system with up to 16 stationsLM unit wiring Connection of station plug to jack Mounting option unit Bl unitMounting other option units than the Bl unit Alarm tone, etc Bl unit connectionBGM equipment PTT.C PTT control RC unit connectionDoor locking Radio Station EquipmentPC unit connection Maximum contact capacity 125 VA 125V AC or 30V DC 1ASerial data output Tl unit connection SM unit number setting Connection for speaker station Service distanceVoltage selector Connection of power sourceInitial set-up and programming No programming Procedures of initial set-up and No programmingDoor remote control 2 circuits PA paging & power remote/3-channel general purpose controlTransfer Secretary transfer Hurry upEX-610/620/630 Registration of each functionHighest Executive Priority Continuous Calling Tone Will be heard Times Be sure to depress Key SteadilyTouch Stations Allowed Access to Paging Allowed Station No Stations Allowed Access to Emergency CallWill be heard Handset Station RegistrationTimes Be sure to depress Key Steadily Have this FunctionAllowed Stations Allowed Access to Speech MessageDoor Substation Registration Release finished? Secretary TransferMASTER/SUB Relationship Registration of Stations to Refuse ALL-CALL Paging Dial Will be heard Times Registration of Station to Refuse Zone 1 PagingRepeat twice Registration of next allowed station Registration of Stations to Refuse Zone 2 PagingRegistration of Stations to Refuse Zone 3 Paging Step Speech and Function Tests Speech Test Performance TestMethod of Speech test Hands-free conversation Handset conversationTrouble-shooting at the time of installation Replace station Noise is heard from the stationDoor Substation Function Table for StationsStation Data Table Station Data Table3 0 6 1 3 5 6 C