Central control unit CC-20:

This unit is comprised of a CPU that processes the exchange procedures, a speech link consisting of a

voice switch circuit and a signal tone generating circuit, and a power circuit.

Line modem unit LM-20:

This unit is comprised of a circuit for sending out signals from the station to the speech path, a circuit to transmit signals from the speech link to the station, a receiver and a scanning circuit for dial data, and a terminal block. Wires from the station are connected directly to the terminal block on the LM unit. A maximum of 4 stations can be connected per LM unit, and up to 4 LM units can be mounted in the EX-200 and FC-210.

BGM unit BI-20:

This unit is comprised of a circuit to send out signals from BGM equipment, and alarm or time signals to the LM unit, a circuit that transmits control signals from the alarm or timer to the CPU, and a terminal block. The Bl unit is mounted in the exchange from the bay solely intended for this unit.

Remote control unit RC-20:

This unit is formed from relays for door remote control, power remote control and PTT control, a circuit to

activate these relays, and a terminal block. It is possible to use any bay for "option" unit to mount the

RC-20 in the exchange.

Pager control unit PC20:

This unit has the control output to remotely operate the TR-321 or TR-322 pager controller as well as the serial data output that complies with ESPA standards. The PC-20 may be mounted in the exchange from any bay for "option" unit.

Speech message unit SM-20:

This unit includes a circuit to convert audio signals into digital signals, a memory storing the converted

signals, and a circuit that converts digital signals into audio signals. A single SM unit has a memory

covering 4 stations, and a control circuit. A maximum of 5 SM units can be mounted in the EX-200 exchange (in this event, no room is left for mounting the RC unit, PC unit and Tl unit in the exchange), and up to 6 in the FC-210 cabinet. However, an entire system can only accept up to 8 of the SM-20 unit.

Tie-line unit TI-20:

This unit is comprised of DTMF transmitting and receiving circuits for exchanging dial data with the other exchange, and a circuit for transmitting voice signals.

Power transformer unit PU-200:

This unit supplies power to the EX-200 and the FC-210. Power output is 20V AC, 2.5 amperes for both

exchanges.

Extension cabinet FC-210:

This unit is employed when a system has more than 16 stations or a number of "option" units are used. A maximum of 4 LM-20's and 6 "option" units can be mounted in the FC-210. Note that the YR-820 and YR-821 cables are necessary for adding the LM-20 and the "option" unit, respectively.

– 3 –

Image 4
Contents EX-200 Contents Before Reading this Hand BookDescription and features Examples of system configurationPower BGM distribution up to 3 channelsRemote control unit RC-20 Power transformer unit PU-200Central control unit CC-20 Line modem unit LM-20Installation of equipment Installing and adjusting proceduresSelection of the place to install Installation of the exchange DimensionsInstalling FC-210 extension cabinet Installation of PU-200 power supply unit Wall Base Case For case Switch boxFor plate Cable installation R51 or R59 390k ohms on the LM unit corresponding toExchange Indoor ExchangeterminalStations boardConnection of equipment Addition of LM unitEstablishment of the LM unit number Mounting LM unit For the system with up to 16 stationsLM unit wiring Mounting option unit Bl unit Connection of station plug to jackMounting other option units than the Bl unit Bl unit connection Alarm tone, etcBGM equipment RC unit connection PTT.C PTT controlDoor locking Radio Station EquipmentMaximum contact capacity 125 VA 125V AC or 30V DC 1A PC unit connectionSerial data output Tl unit connection SM unit number setting Service distance Connection for speaker stationConnection of power source Voltage selectorProcedures of initial set-up and No programming Initial set-up and programming No programmingPA paging & power remote/3-channel general purpose control Door remote control 2 circuitsTransfer Secretary transfer Hurry upRegistration of each function EX-610/620/630Highest Executive Priority Will be heard Times Be sure to depress Key Steadily Continuous Calling ToneTouch Stations Allowed Access to Paging Stations Allowed Access to Emergency Call Allowed Station NoHandset Station Registration Will be heardHave this Function Times Be sure to depress Key SteadilyStations Allowed Access to Speech Message AllowedDoor Substation Registration Secretary Transfer Release finished?MASTER/SUB Relationship Registration of Stations to Refuse ALL-CALL Paging Registration of Station to Refuse Zone 1 Paging Dial Will be heard TimesRegistration of Stations to Refuse Zone 2 Paging Repeat twice Registration of next allowed stationRegistration of Stations to Refuse Zone 3 Paging Step Performance Test Speech and Function Tests Speech TestMethod of Speech test Hands-free conversation Handset conversationTrouble-shooting at the time of installation Noise is heard from the station Replace stationFunction Table for Stations Door SubstationStation Data Table Station Data Table3 0 6 1 3 5 6 C