6-8 Tl unit connection

1-2: Lines for station No.25

3-4: Lines for station No.26

5-6: Tie-line output –10dBm

7-8: Tie-line input –10dBm

No. 25

9-10: Tie-line output –10dBm

11-12 Tie-line input –10dBm

To station No. 25 of exchange A

To station No. 26 of exchange A

No. 26

Exchange A

Exchange B

To station

No. 25 of exchange C

To station

No. 26 of exchange C

Exchange C

To station No. 26 of exchange B

To station No. 25 of exchange B

Note

Dotted lines stand for wiring when two exchanges are connected.

– 16 –

Image 17
Contents EX-200 Before Reading this Hand Book ContentsExamples of system configuration Description and featuresPower BGM distribution up to 3 channelsPower transformer unit PU-200 Remote control unit RC-20Central control unit CC-20 Line modem unit LM-20Selection of the place to install Installing and adjusting proceduresInstallation of equipment Dimensions Installation of the exchangeInstalling FC-210 extension cabinet Installation of PU-200 power supply unit For plate For case Switch boxWall Base Case R51 or R59 390k ohms on the LM unit corresponding to Cable installationExchange Indoor ExchangeterminalStations boardAddition of LM unit Connection of equipmentEstablishment of the LM unit number Mounting LM unit For the system with up to 16 stationsLM unit wiring Mounting other option units than the Bl unit Connection of station plug to jackMounting option unit Bl unit BGM equipment Alarm tone, etcBl unit connection PTT.C PTT control RC unit connectionDoor locking Radio Station EquipmentSerial data output PC unit connectionMaximum contact capacity 125 VA 125V AC or 30V DC 1A Tl unit connection SM unit number setting Connection for speaker station Service distanceVoltage selector Connection of power sourceInitial set-up and programming No programming Procedures of initial set-up and No programmingDoor remote control 2 circuits PA paging & power remote/3-channel general purpose controlTransfer Secretary transfer Hurry upEX-610/620/630 Registration of each functionHighest Executive Priority Touch Continuous Calling ToneWill be heard Times Be sure to depress Key Steadily Stations Allowed Access to Paging Allowed Station No Stations Allowed Access to Emergency CallWill be heard Handset Station RegistrationTimes Be sure to depress Key Steadily Have this FunctionAllowed Stations Allowed Access to Speech MessageDoor Substation Registration Release finished? Secretary TransferMASTER/SUB Relationship Registration of Stations to Refuse ALL-CALL Paging Dial Will be heard Times Registration of Station to Refuse Zone 1 PagingRepeat twice Registration of next allowed station Registration of Stations to Refuse Zone 2 PagingRegistration of Stations to Refuse Zone 3 Paging Step Speech and Function Tests Speech Test Performance TestMethod of Speech test Hands-free conversation Handset conversationTrouble-shooting at the time of installation Replace station Noise is heard from the stationDoor Substation Function Table for StationsStation Data Table Station Data Table3 0 6 1 3 5 6 C