Cisco Systems ATA 188, ATA 186 manual Cadence with Three On-Off Pairs

Page 45

Chapter 5 Parameters and Defaults

Tone Configuration Parameters

TFreq1, TFreq2, and TFreq3 are the transformed frequencies of the first, second, and third frequencies, respectively. Calculate each value with the following formula:

32767 * cos (2 * pi * F/8000)

where F is the desired frequency in Hz. Set this value to 0 if the frequency does not exist. The range of each value is –32768 to 32767.

For negative values, use the 16-bit 2’s complement value. For example, enter –1 as 65535 or as 0xffff.

Tamp1, Tamp2 and Tamp3 are the transformed amplitudes of the first, second and third frequencies, respectively. Their values are calculated with the following formula:

32767 * A * sin(2*pi*F/8000)

A (amplitude factor) = 0.5 * 10^((k+10-(n-1)*3)/20)

where F is the desired frequency in Hz, k is the desired volume in dBm, and n is the number of frequencies (If Sequential is set to 101, n is equal to 1). The ^ symbol means to the order of.

NumOfOnOffPairs is the number of on-off pairs in the cadences of the tone (0, 1, 2, or 3). For a steady tone, use 0.

If this value is 0, the OnTime1, OnTime2, OnTime 3, OffTime1, OffTime2, and OffTime3 values must also be 0.

OnTime1, OnTime2, and OnTime3 are the lengths of time that the first, second, and third on-off pairs of a cadence play a sound, respectively. (See Figure 5-2for a graphical representation.)

Specify each value as a number of samples with the sampling rate of 8 kHz. The range of each value is 0 to 0xffff.

For example, for a length of 0.3 seconds, set a value to 2400.

OffTime1, OffTime2, and OffTime3 are the lengths of silence after the sound of the first, second, and third on-off pairs of a cadence, respectively.

Specify each value as a number of samples with the sampling rate of 8 kHz. The range of each value is 0 to 0xffff.

For example, for a length of 0.3 seconds, set a value to 2400. (See Figure 5-2for a graphical representation.)

Figure 5-2 Cadence with Three On-Off Pairs

Sound

 

 

 

OnTime_1

 

 

 

OnTime_2

 

 

 

OnTime_3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Silence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OffTime_1

OffTime_2

 

 

 

OffTime_3

 

 

 

 

 

 

 

 

 

 

99267

NumOfRepeats is the number of times that the first on-off pair of the cadence (specified by OnTime1, OffTime1) repeats before the second on-off pair (specified by OnTime2, OffTime2) plays.

For example, if NumOfRepeats is 2, the first on-off pair will play three times (it will play once and then repeat two times), then the second on-off pair will play.

TotalToneTime is the total length of time that the tone plays. If this value is 0, the tone will play until another call event stops the tone.

This value is in 10 ms units (100 ms = 1 second).

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for H.323 (version 3.0)

 

OL-4804-01

5-45

 

 

 

Image 45
Contents Parameters and Defaults Configuration Text File Template This section contains only one parameter-UIPassword UIPasswordUser Interface UI Security Parameter Sections that follow describe these parametersUseTFTP Parameters for Configuration Method and EncryptionTftpURL Related ParametersUseTFTP, CfgInterval, CfgInterval DefaultEncryptKey UseTFTP, TftpURL,EncryptKeyEx 320UseTFTP, TftpURL, EncryptKeyEx, Dhcp Network Configuration ParametersNot applicable for this parameter UseTFTP, TftpURL, EncryptKey,StaticIp Voice Configuration Menu Access Code Related ParametersStaticRoute DHCP, StaticRoute, StaticNetMask,Ntpip StaticNetMaskDHCP, StaticIp, StaticNetMask, 255.255.255.0DNS1IP AltNTPIPAltNTPIP, TimeZone, NTPIP, TimeZone,VLANSetting DNS2IPOpFlags, AltGk, AltGkTimeOut, GkTimeToLive, GkId, Disables gatekeeper-routed callsParameters GkOrProxyGkId Default RangeGkTimeToLive AltGkAltGkTimeOut 251AltGk, ConnectMode, page 5-32-Bit This parameter is the password for the Phone 1 port UID1, PWD0, PWD1, UseLoginID, LoginID0, LoginID1,UID0 PWD0UID1 UID0, PWD0, PWD1, UseLoginID, LoginID0, LoginID1,LoginID0 This parameter is the password for the Phone 2 portPWD1 UseLoginID LoginID1LoginID1, PWD0, PWD1, UseLoginID, AutMethod, LoginID0, PWD0, PWD1, UseLoginID, AutMethod,LoginID0, LoginID1, PWD0, PWD1, NTPIP, AltNTPIP, Range Default Voice Configuration Menu Access CodeAutMethod GatewayRange Default Audio Configuration ParametersMediaPort 16384RxCodec TOS, VLANSetting,TxCodec LBRCodec, NumTxFrames, TxCodec, AudioMode,LBRCodec, NumTxFrames, RxCodec, AudioMode, LBRCodec300 AudioMode, page 5-24-Bits 1 TxCodec, RxCodec, NumTxFrames,AudioMode LBRCodec, ConnectMode, RxCodec,Bit Number Definition NumTxFrames ExamplesLBRCodec, RxCodec, TxCodec, TOS Operational Parameters0x0000A8B8 255CallFeatures CallerIdMethod,Bit Number CallFeatures, CallCmd, CallerIdMethod, SigTimer, PaidFeatures315 Call waitingCallCmd CallFeatures, PaidFeatures, CallerIdMethod, SigTimer,Call Waiting Caller ID Maximum of 248 characters317 FeatureTimerSigTimer FeatureTimer2ConnectMode Use fast-start procedure for H.225/Q.931 Use slow-start procedure for H.225/Q.931 and H.245Disable/enable h245 tunneling Disable/enable fax pass-through redundancyOpFlags TftpURL, DHCP, VLANSetting,OpFlags Parameter Operational Features to Turn On or Off TimeZone 302 Telephone Configuration ParametersAdditional Description NTPIP, AltNTPIP,CallerIdMethod Polarity 0x00019e60316 FXSOutputLevel FXSInputLevel304 To 2 dBTone Configuration Parameters Tone Parameter Syntax-Basic FormatRingOnOffTime, Parameters and Defaults Tone Configuration Parameters Tone Parameter Syntax-Extended Formats Extended Format aEach tone is specified by 11 integers, as follows Cadence With Two On-Off Pairs Extended Format BCadence with Three On-Off Pairs ReorderTone Parameter Example1 Component Setting ExplanationReorderTone Parameter Example Recommended Values Default values using the Basic formatSpecific Tone Parameter Information DialToneReorderTone BusyToneCallWaitTone RingbackTone922 923AlertTone RingOnOffTimeDialPlan Dial Plan ParametersRecommended Values DialPlan, DialPlanEx, IPDialPlan,Dial Plan Commands, Dial Plan Rules, Dial Plan Examples, Dial Plan CommandsCisco ATA supports the following dial plan rules Dial Plan RulesSyntax Example‘P’ Rule to Support Dial Prefix Call Prefix prefix+num is shown in the prserv log Log InformationThis rule is for blocking call numbers This rule blocks call numbers beginning with 1900 orSCC CmdCLIP or CLIPnum are shown in the prserv log ‘X’ Rule for Call Blocking and Call Forwarding BlockingFollowing dial plan Dial Plan ExamplesFollowing dial plans Dial Plan ExampleDialPlanEx Diagnostic ParametersIPDialPlan 310SyslogIP NPrintfExtended IP address 0.0.514Bit Number Type of Messages to Trace SyslogCtrlCFGID-Version Parameter for Cisco ATA Configuration File OL-4804-01
Related manuals