Greenheck Fan 473501 manual Optional Control Center Components

Page 18

Typical Control Center Components - individual components and locations will vary

1.

Main disconnect (non-fusible, lockable)

Optional Control Center Components

2.

Motor starter - exhaust air fan

12.

DDC controller

3.

Motor starter - outdoor air fan

13.

Dirty filter pressure switches

4.

Motor contactor - energy wheel

14.

Economizer module

5.

24 VAC control transformer

15.

Thermostats for:

6.

24 VAC terminal strip

 

- Economizer module

7.

Fuses for blower motors

 

- Energy recovery wheel frost control

8.

Grounding lug

16.

Terminal block

9.

Distributor block

17.

Frost control pressure switch

10.

Compressor fuse blocks

18.

Energy recovery wheel VFD

11.

Terminal block

 

 

9

4

3

2

18

10

1

8

7

5

6

17

16

 

 

 

 

 

 

15

 

 

 

 

 

 

14

 

 

 

 

 

 

13

 

 

 

 

 

 

12

 

 

 

 

 

 

11

Component #6

Detail of Terminal Strip

Refer to “Heat Pump System” section for components in compressor compartment

18Model ERCH-HP Energy Recovery Unit

Image 18
Contents General Safety Information Model ERCH-HPUnpacking Inspection and Maintenance during StorageReceiving HandlingTable of Contents Product Overview Models and CapacitiesSubassemblies CoilsHeat Pump Module Location of components in the module will varyInstallation Dimensional DataUnit Weights and Recommended Roof Opening Service Clearances ERCH-HP 20 ERCH-HPLifting Lifting LugsRoof Curb Mounting Curb Outside Dimensions and Weights Install DuctworkSet the Unit Lift Ductwork Connections Rail Mounting / LayoutExhaust Weatherhood Start-Up Unit Pre-Start-Up Checklist Start-Up ProcedureVoltage Imbalance Unit Start-Up Checklist Electrical Information Discharge Air Temperature Sensor Plumbing / Piping OverviewCondensate Drain Trap Indicator Lights powered by the ER Unit Optional Remote Control PanelWiring Schematics Day Timer or On/Off SwitchOptional Control Center Components Timer Electrical ControlsOptional Frost Control Phase Monitor Optional EconomizerVariable Frequency Drive VFD Optional Rotation Sensor Dirty Filter SensorSequence of Operation Adjust the Air SealsEnergy Wheel Start-UpEnergy Wheel Maintenance Energy Wheel Troubleshooting Factory-Installed Heat Pump System ComponentsHeat Pump Overview Heat Pump Controls Refrigeration System Schematic Typical Operating Conditions Unit Protection Module UPM Fault Indications Lockout ResetIntelligent Reset Troubleshooting Controller Alarms DDC ControllerFX05 Furnace Controller Design Airflow Troubleshooting AirflowTroubleshooting Unit Measured AirflowResistance Troubleshooting Refrigeration Circuit Troubleshooting NoteTwo hours. Recheck for open circuit Check bulb for contact Check entering air wet bulb conditions Worn oil pump Replace the oil pump Maintenance Procedures Lubrication Routine MaintenanceMaintenance Frequency DampersFan Motors Fan Wheel and FastenersFan Bearings Internal Filter Maintenance External Filter MaintenanceCoil Maintenance Maintenance Log Warranty

473501 specifications

Greenheck Fan 473501 is a significant player in the world of ventilation solutions, specifically designed to meet the increasing demands for efficiency and effectiveness in air movement. This commercial-grade fan is particularly noted for its high performance and reliability, making it a top choice for various applications, ranging from industrial settings to larger commercial spaces.

One of the main features of the Greenheck 473501 is its energy-efficient design. It is engineered to minimize energy consumption while maximizing airflow, allowing users to achieve optimal performance without incurring high utility bills. The fan is equipped with a powerful motor that not only ensures consistent airflow but also contributes to its overall longevity and durability.

The fan boasts an impressive air performance rating, which is crucial for environments that require precise temperature and humidity control. With adjustable airflow settings, users can customize the fan’s operation to suit specific needs, whether that means circulating air in a warehouse or exhaust in a manufacturing facility.

Another standout characteristic is the fan's robust construction. Built with corrosion-resistant materials, the Greenheck 473501 is ideal for use in harsh environments, where exposure to moisture and other elements could compromise lesser fans. The design also incorporates noise-reducing technologies, making it suitable for settings where quiet operation is essential, such as schools, hospitals, and office buildings.

In terms of installation, the Greenheck 473501 is designed for versatility. It can be easily integrated into various ventilation systems, whether for new constructions or upgrades to existing infrastructure. Its compact footprint allows for convenient placement without sacrificing performance.

Furthermore, Greenheck offers extensive support and resources for this model, ensuring users have access to the information necessary for optimal operation, maintenance, and any potential troubleshooting.

Overall, the Greenheck Fan 473501 represents a harmonious blend of efficiency, durability, and flexibility, making it an ideal choice for those seeking a high-quality ventilation solution that meets contemporary environmental standards while delivering reliable performance across diverse applications.