Greenheck Fan 473501 manual Optional Rotation Sensor, Dirty Filter Sensor

Page 21

Optional Rotation Sensor

The rotation sensor monitors energy wheel rotation. If the wheel should stop rotating, the sensor will close a set of contacts in the unit control center. Field-wiring of a light (or other alarm) between terminals R and 12 in the unit control center will notify maintenance personnel when a failure has occurred.

Dirty Filter Sensor

Dirty filter sensors monitor pressure drop across the outdoor air filters, exhaust air filters, or both. If the pressure drop across the filters exceeds the set point, the sensor will close a set of contacts in the unit control center. Field-wiring of a light (or other alarm) to these contacts will notify maintenance personnel when filters need to be replaced. The switch has not been set at the factory due to external system losses that will affect the switch. This switch will need minor field adjustments after the unit has been installed with all ductwork complete. The dirty filter switch is mounted in the exhaust inlet compartment next to the unit control center or in unit control center.

Setscrew (on front of switch) must be manually adjusted after the system is in operation.

Negative pressure connection

is toward the ‘front or top’ of the switch. (senses pressure on the blower side of filters)

Positive pressure connection is toward the ‘back or bottom’ of the switch. (senses pressure at air inlet side of filters)

To adjust the switch, the unit must be running with all of the access doors in place, except for the compartment where the switch is located (exhaust intake compartment). The adjusting screw is located on the top of the switch. Open the filter compartment and place a sheet of plastic or cardboard over 50% of the filter media. Replace the filter compartment door. Check to see if there is power at the alert signal leads. Whether there is power or not, turn the adjustment screw on the dirty filter gauge (clockwise if you did not have power, counterclockwise if you did have power) until the power comes on or just before the power goes off. Open the filter compartment and remove the obstructing material. Replace the door and check to make sure that you do not have power at the alert signal leads. The unit is now ready for operation.

Model ERCH-HP Energy Recovery Unit 21

Image 21
Contents Model ERCH-HP General Safety InformationReceiving Inspection and Maintenance during StorageUnpacking HandlingTable of Contents Models and Capacities Product OverviewCoils SubassembliesLocation of components in the module will vary Heat Pump ModuleInstallation Dimensional DataUnit Weights and Recommended Roof Opening ERCH-HP 20 ERCH-HP Service ClearancesLifting Lugs LiftingRoof Curb Mounting Curb Outside Dimensions and Weights Install DuctworkSet the Unit Lift Ductwork Connections Rail Mounting / LayoutExhaust Weatherhood Start-Up Unit Pre-Start-Up Checklist Start-Up ProcedureVoltage Imbalance Unit Start-Up Checklist Electrical Information Discharge Air Temperature Sensor Plumbing / Piping OverviewCondensate Drain Trap Wiring Schematics Optional Remote Control PanelIndicator Lights powered by the ER Unit Day Timer or On/Off SwitchOptional Control Center Components Timer Electrical ControlsOptional Frost Control Phase Monitor Optional EconomizerVariable Frequency Drive VFD Dirty Filter Sensor Optional Rotation SensorEnergy Wheel Adjust the Air SealsSequence of Operation Start-UpEnergy Wheel Maintenance Energy Wheel Troubleshooting Factory-Installed Heat Pump System ComponentsHeat Pump Overview Heat Pump Controls Refrigeration System Schematic Typical Operating Conditions Unit Protection Module UPM Fault Indications Lockout ResetIntelligent Reset Troubleshooting Controller Alarms DDC ControllerFX05 Furnace Controller Troubleshooting Unit Troubleshooting AirflowDesign Airflow Measured AirflowResistance Troubleshooting Note Troubleshooting Refrigeration CircuitTwo hours. Recheck for open circuit Check bulb for contact Check entering air wet bulb conditions Worn oil pump Replace the oil pump Maintenance Frequency Routine MaintenanceMaintenance Procedures Lubrication DampersFan Motors Fan Wheel and FastenersFan Bearings Internal Filter Maintenance External Filter MaintenanceCoil Maintenance Maintenance Log Warranty

473501 specifications

Greenheck Fan 473501 is a significant player in the world of ventilation solutions, specifically designed to meet the increasing demands for efficiency and effectiveness in air movement. This commercial-grade fan is particularly noted for its high performance and reliability, making it a top choice for various applications, ranging from industrial settings to larger commercial spaces.

One of the main features of the Greenheck 473501 is its energy-efficient design. It is engineered to minimize energy consumption while maximizing airflow, allowing users to achieve optimal performance without incurring high utility bills. The fan is equipped with a powerful motor that not only ensures consistent airflow but also contributes to its overall longevity and durability.

The fan boasts an impressive air performance rating, which is crucial for environments that require precise temperature and humidity control. With adjustable airflow settings, users can customize the fan’s operation to suit specific needs, whether that means circulating air in a warehouse or exhaust in a manufacturing facility.

Another standout characteristic is the fan's robust construction. Built with corrosion-resistant materials, the Greenheck 473501 is ideal for use in harsh environments, where exposure to moisture and other elements could compromise lesser fans. The design also incorporates noise-reducing technologies, making it suitable for settings where quiet operation is essential, such as schools, hospitals, and office buildings.

In terms of installation, the Greenheck 473501 is designed for versatility. It can be easily integrated into various ventilation systems, whether for new constructions or upgrades to existing infrastructure. Its compact footprint allows for convenient placement without sacrificing performance.

Furthermore, Greenheck offers extensive support and resources for this model, ensuring users have access to the information necessary for optimal operation, maintenance, and any potential troubleshooting.

Overall, the Greenheck Fan 473501 represents a harmonious blend of efficiency, durability, and flexibility, making it an ideal choice for those seeking a high-quality ventilation solution that meets contemporary environmental standards while delivering reliable performance across diverse applications.