Greenheck Fan 473501 manual Heat Pump Module, Location of components in the module will vary

Page 6
Unit Protection Module
(UPM)

Heat Pump Module

Every unit has an integral heat pump module that contains hermetic scroll-type compressor(s), a coaxial refrigerant-to-water heat exchanger(s), refrigerant flow reversing valve(s), expansion valve(s), liquid line filter drier, high pressure manual reset cutout, crankcase heater(s) and various sensors, service ports and safety devices which allows the unit to run at less than full capacity and results in fewer compressor cycles. The heat pump is intended to be connected to an external water source such as a water cooling tower or boiler, a geothermal source or even a ground loop. The module is piped to the airside coil located in the intake airstream and optionally to a reheat coil that will control humidity.

The location of components in the module will vary.

Control circuitry and the Unit Protection Module (UPM) for the heat pump module are located in the heat pump module. The UPM is a

printed circuit board and has LED fault indicator lights to indicate various alarm conditions and also power status. A unit- specific schematic for electrical circuits is located in the control center and another unit-specific schematic for heat pump

circuitry is located in the heat pump module.

Optional Electric Heaters

There are two optional electric heaters available. One is a preheater and is used to prevent frost buildup on the energy wheel. It is located directly in front of the intake air filter assembly. The second optional heater is used as a supplementary emergency heat source for the building and is integrated into the supply airstream.

Optional Electric

Optional Electric

Preheater Location

Heater Location

 

Supply Air Motor and

Blower Assembly

Optional Indirect Gas Furnace

An optional indirect gas furnace may be installed and provides supplementary emergency heat to the building. A complete Installation, Operation and Maintenance Manual for the furnace is provided with the unit. A unit- specific wiring diagram is located inside the furnace housing access door.

High Efficiency

Scroll Type

Compressors

Coaxial

Refrigerant-

to-Water Heat

Exchangers

Heat Pump Module

Refrigerant

Reversing

Valves

Indirect Gas Furnace

Water Intake

and Discharge

Connections

6Model ERCH-HP Energy Recovery Unit

Image 6
Contents General Safety Information Model ERCH-HPUnpacking Inspection and Maintenance during StorageReceiving HandlingTable of Contents Product Overview Models and CapacitiesSubassemblies CoilsHeat Pump Module Location of components in the module will varyInstallation Dimensional DataUnit Weights and Recommended Roof Opening Service Clearances ERCH-HP 20 ERCH-HPLifting Lifting LugsRoof Curb Mounting Curb Outside Dimensions and Weights Install DuctworkSet the Unit Lift Ductwork Connections Rail Mounting / LayoutExhaust Weatherhood Start-Up Unit Pre-Start-Up Checklist Start-Up ProcedureVoltage Imbalance Unit Start-Up Checklist Electrical Information Discharge Air Temperature Sensor Plumbing / Piping OverviewCondensate Drain Trap Indicator Lights powered by the ER Unit Optional Remote Control PanelWiring Schematics Day Timer or On/Off SwitchOptional Control Center Components Timer Electrical ControlsOptional Frost Control Phase Monitor Optional EconomizerVariable Frequency Drive VFD Optional Rotation Sensor Dirty Filter SensorSequence of Operation Adjust the Air SealsEnergy Wheel Start-UpEnergy Wheel Maintenance Energy Wheel Troubleshooting Factory-Installed Heat Pump System ComponentsHeat Pump Overview Heat Pump Controls Refrigeration System Schematic Typical Operating Conditions Unit Protection Module UPM Fault Indications Lockout ResetIntelligent Reset Troubleshooting Controller Alarms DDC ControllerFX05 Furnace Controller Design Airflow Troubleshooting AirflowTroubleshooting Unit Measured AirflowResistance Troubleshooting Refrigeration Circuit Troubleshooting NoteTwo hours. Recheck for open circuit Check bulb for contact Check entering air wet bulb conditions Worn oil pump Replace the oil pump Maintenance Procedures Lubrication Routine MaintenanceMaintenance Frequency DampersFan Motors Fan Wheel and FastenersFan Bearings Internal Filter Maintenance External Filter MaintenanceCoil Maintenance Maintenance Log Warranty

473501 specifications

Greenheck Fan 473501 is a significant player in the world of ventilation solutions, specifically designed to meet the increasing demands for efficiency and effectiveness in air movement. This commercial-grade fan is particularly noted for its high performance and reliability, making it a top choice for various applications, ranging from industrial settings to larger commercial spaces.

One of the main features of the Greenheck 473501 is its energy-efficient design. It is engineered to minimize energy consumption while maximizing airflow, allowing users to achieve optimal performance without incurring high utility bills. The fan is equipped with a powerful motor that not only ensures consistent airflow but also contributes to its overall longevity and durability.

The fan boasts an impressive air performance rating, which is crucial for environments that require precise temperature and humidity control. With adjustable airflow settings, users can customize the fan’s operation to suit specific needs, whether that means circulating air in a warehouse or exhaust in a manufacturing facility.

Another standout characteristic is the fan's robust construction. Built with corrosion-resistant materials, the Greenheck 473501 is ideal for use in harsh environments, where exposure to moisture and other elements could compromise lesser fans. The design also incorporates noise-reducing technologies, making it suitable for settings where quiet operation is essential, such as schools, hospitals, and office buildings.

In terms of installation, the Greenheck 473501 is designed for versatility. It can be easily integrated into various ventilation systems, whether for new constructions or upgrades to existing infrastructure. Its compact footprint allows for convenient placement without sacrificing performance.

Furthermore, Greenheck offers extensive support and resources for this model, ensuring users have access to the information necessary for optimal operation, maintenance, and any potential troubleshooting.

Overall, the Greenheck Fan 473501 represents a harmonious blend of efficiency, durability, and flexibility, making it an ideal choice for those seeking a high-quality ventilation solution that meets contemporary environmental standards while delivering reliable performance across diverse applications.