Page 2

Receiving

Upon receiving the product, check to make sure all items are accounted for by referencing the bill of lading to ensure all items were received. Inspect each crate for shipping damage before accepting delivery. Notify the carrier if any damage is noticed. The carrier will make notification on the delivery receipt acknowledging any damage to the product. All damage should be noted on all the copies of the bill of lading which is countersigned by the delivering carrier. A Carrier Inspection Report should be filled out by the carrier upon arrival and filed with the Traffic Department. If damaged upon arrival, file claim with carrier. Any physical damage to the unit after acceptance is not the responsibility of the manufacturer.

Unpacking

Verify that all required parts and the correct quantity of each item have been received. If any items are missing, report shortages to your local representative to arrange for obtaining missing parts. Sometimes it is not possible that all items for the unit be shipped together due to availability of transportation and truck space. Confirmation of shipment(s) must be limited to only items on the bill of lading.

Handling

Units are to be rigged and moved by the lifting brackets provided or by the skid when a forklift is used. Number and location of lifting brackets varies by model and size. Handle each piece in such a manner as to keep from scratching or chipping the coating. Damaged finish may reduce ability of the unit to resist corrosion.

Storage

Units are protected against damage during shipment. If the unit cannot be installed and operated immediately, precautions need to be taken to prevent deterioration of the unit during storage. The user assumes responsibility of the unit and accessories while in storage. The manufacturer will not be responsible for damage during storage. These suggestions are provided solely as a convenience to the user.

Inspection and Maintenance during Storage

While in storage, inspect units once per month. Keep a record of inspection and maintenance performed.

If moisture or dirt accumulations are found on parts, the source should be located and eliminated. At each inspection, rotate all moving components by hand ten to fifteen revolutions to distribute lubricant on motor and bearings. If paint deterioration begins, consideration should be given to touch-up or repainting. Units with special coatings may require special techniques for touch-up or repair.

Machined parts coated with rust preventive should be restored to good condition promptly if signs of rust occur. Immediately remove the original rust preventive coating with petroleum solvent and clean with lint-free cloths. Polish any remaining rust from surface with crocus cloth or fine emery paper and oil. Do not destroy the continuity of the surfaces. Wipe clean thoroughly with Tectyl® 506 (Ashland Inc.) or the equivalent.

For hard to reach internal surfaces or for occasional use, consider using Tectyl® 511M Rust Preventive or WD‑40® or the equivalent.

2Model ERCH-HP Energy Recovery Unit

Image 2
Contents General Safety Information Model ERCH-HPUnpacking Inspection and Maintenance during StorageReceiving HandlingTable of Contents Product Overview Models and CapacitiesSubassemblies CoilsHeat Pump Module Location of components in the module will varyUnit Weights and Recommended Roof Opening InstallationDimensional Data Service Clearances ERCH-HP 20 ERCH-HPLifting Lifting LugsSet the Unit Lift Roof Curb Mounting Curb Outside Dimensions and WeightsInstall Ductwork Exhaust Weatherhood Ductwork ConnectionsRail Mounting / Layout Start-Up Unit Voltage Imbalance Pre-Start-Up ChecklistStart-Up Procedure Unit Start-Up Checklist Electrical Information Condensate Drain Trap Discharge Air Temperature SensorPlumbing / Piping Overview Indicator Lights powered by the ER Unit Optional Remote Control PanelWiring Schematics Day Timer or On/Off SwitchOptional Control Center Components Optional Frost Control TimerElectrical Controls Variable Frequency Drive VFD Phase MonitorOptional Economizer Optional Rotation Sensor Dirty Filter SensorSequence of Operation Adjust the Air SealsEnergy Wheel Start-UpEnergy Wheel Maintenance Heat Pump Overview Energy Wheel TroubleshootingFactory-Installed Heat Pump System Components Heat Pump Controls Refrigeration System Schematic Typical Operating Conditions Intelligent Reset Unit Protection Module UPM Fault IndicationsLockout Reset FX05 Furnace Controller Troubleshooting Controller AlarmsDDC Controller Design Airflow Troubleshooting AirflowTroubleshooting Unit Measured AirflowResistance Troubleshooting Refrigeration Circuit Troubleshooting NoteTwo hours. Recheck for open circuit Check bulb for contact Check entering air wet bulb conditions Worn oil pump Replace the oil pump Maintenance Procedures Lubrication Routine MaintenanceMaintenance Frequency DampersFan Bearings Fan MotorsFan Wheel and Fasteners Coil Maintenance Internal Filter MaintenanceExternal Filter Maintenance Maintenance Log Warranty

473501 specifications

Greenheck Fan 473501 is a significant player in the world of ventilation solutions, specifically designed to meet the increasing demands for efficiency and effectiveness in air movement. This commercial-grade fan is particularly noted for its high performance and reliability, making it a top choice for various applications, ranging from industrial settings to larger commercial spaces.

One of the main features of the Greenheck 473501 is its energy-efficient design. It is engineered to minimize energy consumption while maximizing airflow, allowing users to achieve optimal performance without incurring high utility bills. The fan is equipped with a powerful motor that not only ensures consistent airflow but also contributes to its overall longevity and durability.

The fan boasts an impressive air performance rating, which is crucial for environments that require precise temperature and humidity control. With adjustable airflow settings, users can customize the fan’s operation to suit specific needs, whether that means circulating air in a warehouse or exhaust in a manufacturing facility.

Another standout characteristic is the fan's robust construction. Built with corrosion-resistant materials, the Greenheck 473501 is ideal for use in harsh environments, where exposure to moisture and other elements could compromise lesser fans. The design also incorporates noise-reducing technologies, making it suitable for settings where quiet operation is essential, such as schools, hospitals, and office buildings.

In terms of installation, the Greenheck 473501 is designed for versatility. It can be easily integrated into various ventilation systems, whether for new constructions or upgrades to existing infrastructure. Its compact footprint allows for convenient placement without sacrificing performance.

Furthermore, Greenheck offers extensive support and resources for this model, ensuring users have access to the information necessary for optimal operation, maintenance, and any potential troubleshooting.

Overall, the Greenheck Fan 473501 represents a harmonious blend of efficiency, durability, and flexibility, making it an ideal choice for those seeking a high-quality ventilation solution that meets contemporary environmental standards while delivering reliable performance across diverse applications.