Heat Controller VMH09SC-1, VMH12SC-1  Operational,  Keep level even when installing the product

Page 6

Service Manual

VMH Series

Heat Controller, Inc.

 

 

 

Keep level even when installing the product.

To avoid vibration of water leakage.

Use two or more people to lift and transport the product.

Avoid personal injury.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins,

could cause product malfunction or inefficient operation.

Operational

Do not expose the skin directly to cool air for long periods of time. (Do not sit in the

draft).

This could harm to your health.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigerant system.

There is risk of damage or loss of property.

Do not block the inlet or outlet of air flow.

It may cause product failure.

Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.

There is risk of fire, electric shock, or damage to the plastic parts of the product.

Do not touch the metal parts of the product when removing the air filter. They are very

sharp.

There is risk of personal injury.

Do not step on or put anything on the product. (outdoor units)

There is risk of personal injury and failure of product.

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

6

Image 6
Contents Inverter Single Zone Ductless Mini Split Heat Pump Contents Precaution Safety Precaution Installation  For installation, always contact the dealer  Caution  Use two or more people to lift and transport the product  Keep level even when installing the product Operational  Do not block the inlet or outlet of air flow Do not drink the water drained from the product Function Anti-freeze protection in coolingOutdoor unit Compressor delay Dimension Indoor UnitModel Dimension mm Outdoor UnitRefrigerant Cycle Diagram Indoor OutdoorWiring Diagrams VMH09SC-1 A-VMH12SC-1 VMH18SC-1 Installation details Pipe length and the elevation Single Zone V Series Inverter SystemPressure Test & Evacuation System Evacuation and ChargingOperation characteristics Electronic function AbbreviationDisplay function Main Protection Operation Modes and Functions Preheat modeFan only mode Preheat terminationCooling Mode Compressor running rules Frequency decreases Holds Model CurrentCondenser high temperature T3 protection Outdoor fan rulesIndoor fan running rules Evaporator low temperature T2 protection Heating Mode Compressor running rulesT1-Ts-ΔT +5.0 +4.5 +3.5 +3.0 +2.5 +2.0 +1.5 +1.0 +0.5 I1HEAT I2HEAT I3HEAT Outdoor fan running rulesVMH12SC-1 Indoor fan rulesUnit TEL0 TEL1 VMH09SC-1 VMH18SC-1Defrost mode: Defrost Actions For 9K and 12K unit For 18K and 24K unit High evaporator coil temp.T2 protection Auto-modeDehumidify mode Forced operation functionTimer function Sleep function modeIonizer Clean Air function Auto-Restart functionAutomatic front panel function Troubleshooting SafetyIndoor Unit Error Display Diagnosis and SolutionEeprom parameter error diagnosis and solution VMH Series E3 Indoor or E7 Outdoor Igbt over current protection diagnosis and solution VMH Series 29 P3 Error Low Ambient Protection Inverter compressor drive error diagnosis and solutionKey parts checking Position Resistance ValueVMH Series Some frequently-used R-T data for T1, T2, T3 and T4 sensor 2012