Heat Controller DMC24DB-1, DMH36TB-1 manual There is risk of fire or electrical shock

Page 6

Safety Precautions

Stop operation and close any window in storm or hurricane. before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

Ventilate the product from time to time when operating it together with a stove, etc.

There is risk of fire or electrical shock.

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product.

Turn off breaker to the appliance before performing cleaning or maintenance.

• There is risk of electric shock.

When the product is soaked (flooded or submerged), contact an Authorized Service Center.

• There is risk of electrical shock.

When the product is not being used for a long time turn off the breaker.

There is risk of product damage or failure, or unintended operation.

Take care to ensure that nobody could step on or fall onto the outdoor unit.

There could result in personal injury and product damage.

Do not insert hands or other objects through the air inlet or outlet while the air conditioner is on.

There are sharp and moving parts that could cause personal injury.

6Room Air Conditioner

Image 6
Contents DMC24DB-1, DMH24DB-1 DMC36TB-1, DMH36TB-1 Table of Contents Installation Parts Provided 24k 36k Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk of fire, electric shock, explosion or injury There is risk of fire or product failure Could cause personal injury Personal injuryMoisture may condense and wet or damage furnishings Oxygen deficiency could occurThere is risk of electrical shock There is risk of fire or electrical shockThere is risk of electric shock There could result in personal injury and product damageThis could damage your health It may cause a problem for your neighborsAvoid personal injury There is risk of damage or loss of propertyThere is risk of personal injury and failure of product It is not sanitary and could cause serious health issuesThere is risk of personal injury Be careful and avoid personal injurySelect the best location Installation of Indoor, Outdoor UnitRooftop Installations Indoor unitPiping length and elevation Multi Piping Type24k 36k Fixing Installation Plate Drill a hole in the wallBurrs removal Flaring workCut the pipes and the cable Putting nut onIndoor Connecting the PipingCheck Foamed polyethylene or equivalent is recommendedKg .mlbf .ft Indoor unit installationOutside diameter Torque Flare nut PipesIndoor unit Spacer Open-end wrench fixed Flare nut WrenchIndoor unit tubing Piping for Piping holeGood case Bad caseOutdoor Outside diameter TorqueConnect the cable to the Indoor unit Power supply Connect the cable to the Outdoor unitWith the screw How to connect wiring to the terminals Circuit Breaker MOC rating on the unit rating plate Drain piping Checking the drainageTo check the drainage Pour a glass of water on the evaporatorForming the piping Seal a small Opening around Pipings withGum type sealer Air Purging and Evacuation Checking methodRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Charging Max totalAdditional Prepare remote control Test RunningEvaluation of the performance Heat CONTROLLER, INC