Installation

Figure 2: HTS Installation

External Flow Controller Mounting

The Flow Controller can be mounted beside the unit as shown in Figure 4. Review the Flow Controller installa- tion manual for more details.

Water Connections-Residential (Distributor) Models Residential models utilize swivel piping fittings for water connections that are rated for 450 psi (3101 kPa) operat- ing pressure. The connections have a rubber gasket seal similar to a garden hose gasket, which when mated to the flush end of most 1” threaded male pipe fittings pro- vides a leak-free seal without the need for thread sealing tape or joint compound. Insure that the rubber seal is in the swivel connector prior to attempting any connection (rubber seals are shipped attached to the swivel connec- tor). DO NOT OVER TIGHTEN or leaks may occur.

The female locking ring is threaded onto the pipe threads which holds the male pipe end against the rubber gasket, and seals the joint. HAND TIGHTEN ONLY! DO NOT OVERTIGHTEN!

Figure 3: Water Connections (Indoor Compressor Section)

Swivel Nut

 

Hand Tighten

 

Only!

Stainless steel

Do Not

snap ring

Overtighten!

Gasket

Brass Adaptor

GROUND-LOOP HEAT PUMP APPLICATIONS

CAUTION!

CAUTION! The following instructions represent industry accepted installation practices for closed loop earth coupled heat pump systems. Instructions are provided to assist the contractor in installing trouble free ground loops. These instructions are recommendations only. State/provincial and local codes MUST be followed and installation MUST conform to ALL applicable codes. It is the responsibility of the installing contractor to determine and comply with ALL applicable codes and regulations.

Pre-Installation

Prior to installation, locate and mark all existing underground utilities, piping, etc. Install loops for new construction before

sidewalks, patios, driveways, and other construction has begun. During construction, accurately mark all ground loop piping on the plot plan as an aid in avoiding potential future damage to the installation.

Piping Installation

The typical closed loop ground source system is shown in Figure 3. All earth loop piping materials should be limited to polyethylene fusion only for in-ground sections of the loop. Galvanized or steel fittings should not be used at any time due to their tendency to corrode. All plastic to metal threaded fittings should be avoided due to their potential to leak in earth coupled applications. A flanged fitting should be substituted. P/T plugs should be used so that flow can be measured using the pressure drop of the unit heat exchanger.

www.heatcontroller.com

9

Image 9
Contents GeoLogix HTS Series Split System Two Stage, 2-5 Tons Table of Contents Model Nomenclature for Indoor Split Series Safety SafetyGeneral Information General Equipment SelectionIndoor Coil Selection HTS GeoLogix WDG/MWG Indoor Section Matches for Ahri RatingsSelecting Air Handler Air Handler Selection ExampleRemoving Existing Condensing Unit Where Applicable InstallationAir Handler and Coil Installation Indoor Compressor Section LocationPiping Installation HTS InstallationGround-Loop Heat Pump Applications Flushing the Earth LoopAntifreeze Antifreeze Percentages by Volume Approximate Fluid Volume U.S. gal. L per 100’ of Pipe100% USP food grade Propylene Glycol EthanolWater Quality Standards Expansion Tank and PumpMotorized Modulating Water Control Valve 026-049 Sizes 064 Ground-Water Heat Pump ApplicationsClosed OpenWater Quality Standards Water Quality StandardsLine Set Installation Refrigeration InstallationInstalling the Indoor Coil and Lineset Add-On Heat Pump ApplicationsEvacuation and Charging the Unit WDG Evacuation Of The Lineset And Coil Charging The SystemTotal Charge Method Determining Sub-Cooling Checking Superheat and Subcooling Determining SuperheatHot Water Generator Typical HWG Installation Indoor Compressor SectionWater Tank Preparation InstallationWater Tank Refill HWG Water PipingInitial Start-Up HWG Water Piping Sizes and LengthGeoMax 2 HTS Electrical Data Electrical Line VoltageAccessory Connections Low Water Temperature Cutout SelectionElectrical Low Voltage Terminal StripElectrical Thermostat Wiring Thermostat InstallationThermostat Connections Unit Operation DXM2 ControlsDXM2 Layout and Connections Indoor Split HTS024-060 Wiring Diagram 208-230-/60/1 DXM2 Operating Limits Unit Commissioning And Operating ConditionsBuilding Operating Limits Commissioning ConditionsUnit Start-up Procedure Unit Start-Up and Operating ConditionsUnit and System Checkout Manual Operation Unit Start-Up ProcedureGPM Unit Operating ConditionsTon Preventive Maintenance Sensor Nominal resistance at various temperatures Basic Troubleshooting InformationSystem Configuration Advanced Troubleshooting and Configuration InformationService Mode Start DXM2 Process Flow ChartFault Htg Clg Possible Cause Solution Functional TroubleshootingIFC Fault Code Symptom Htg Clg Possible Cause Solution Performance Troubleshooting\SH Troubleshooting FormS i d e n t i a l S p l i t 6 0 H z R 4 1 0 a Wellworth Ave., Jackson, Michigan 49203 Ph -0787-2100 Fax

HTS SERIES specifications

The Heat Controller HTS Series is a cutting-edge solution for climate control, designed to offer superior performance and unmatched comfort. This advanced heating and cooling system stands out in today's market due to its innovative technologies and user-friendly features.

One of the main features of the HTS Series is its energy efficiency. Equipped with the latest inverter technology, it adjusts the compressor speed to maintain the desired temperature while consuming less energy. This not only reduces operational costs but also minimizes the carbon footprint, making it an environmentally friendly choice.

Another standout characteristic of the HTS Series is its precise temperature control. The system utilizes advanced sensors to monitor indoor conditions in real-time, ensuring that you experience consistent comfort throughout your space. The ability to quickly react to changes in temperature helps maintain an optimal environment, regardless of external weather fluctuations.

The HTS Series also boasts a robust air filtration system. With multiple filter layers, including HEPA filters, it effectively captures dust, allergens, and other airborne pollutants. This feature makes the HTS Series an excellent choice for families with allergies or respiratory concerns, promoting a healthier indoor atmosphere.

Furthermore, the heat pump technology incorporated in the HTS Series allows for both heating and cooling capabilities. In cooler months, it efficiently extracts heat from the outside air to warm your living spaces, while during the summer, it reverses the process to provide refreshing cool air. This dual functionality enhances versatility, making it suitable for various climates.

User convenience is paramount in the HTS Series design. It comes with a smart thermostat that enables remote operation via a mobile app, providing users with flexible control over their environment. Additionally, the intuitive interface and programmable settings allow for seamless customization, adapting to your daily schedule and preferences.

Durability and quiet operation are also key attributes of the HTS Series. Built with high-quality materials and components, it ensures long-lasting performance, while its sound-dampening technologies provide whisper-quiet operation, enhancing the comfort of your home or office space.

In summary, the Heat Controller HTS Series represents the pinnacle of home heating and cooling technology. With its energy efficiency, precise temperature control, superior air filtration, dual functionality, and user-friendly features, it stands as a leading choice for those seeking reliable and effective climate solutions. This series not only enhances comfort but also supports a sustainable lifestyle for the future.