Installation of Indoor Unit

(1)Install the indoor unit level on a strong wall which is not subject to vibration.

(2)The inlet and outlet ports should not be obstructed : the air should be able to blow all over the room.

(3)Do not install the unit where it will be exposed to direct sunlight ,

(4)Install the unit where connection to the outdoor unit is easy.

(5)Install the unit where the drain pipe can be easily installed.

(6)Take servicing , etc.into consideration and leave the spaces shown in (Fig.1 or 2) . Also install the unit where the filter can be removed .

Fig. 1

Ceiling

INDOOR UNIT

3"(80mm)

6"(150mm)

over

over

0.4"(10mm)

over

FOR HALF CONCEALED INSTALLATION

Ceiling panel

 

Fig. 2

 

INDOOR UNIT

 

3"(80mm)

6"(150mm)

over

over

Ceiling panel

0.4"(10mm)

over

13

Image 15
Contents Operation & Installation Manual Contents Disposal of the old air conditioner ERA EAASafety Precautions Safety Precautions Automatic Operation Features and FunctionsPress the AIR Flow Direction Horizontal SET button Press the AIR Flow Direction Vertical SET buttonRIGHT/LEFT For series 282, 362, 422, 482 Name of PartsFollowing four procedures are for series 282, 362, 422, 482 Cleaning and CareOperation and Performance Heating Performance Operation TipsLocation Installation of Indoor UnitSelecting the Mounting Position Indoor Unit Supension-bolt pitch should be as shown Install the room air conditioner as followsDrilling the Holes and Attaching the Suapension Bolts For HALF-CONCESLED Installation Flat washer Installing the Coupler Heat InsulationGood Badbad Installation of Indoor Unit Electrical Wiring Electrical Requirement FRESH-AIR Intake T N 1 2 Customer Guidance Followings are not problems Trouble ShootingPoor cooling Poor cooling or heatingRemarks SeriesError display For EAA series Haier Group