Safety Precautions

WARNING!

The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3 mm. Such means for disconnection must be incorporation in the fixed wiring.

Use copper wire only. All the cables shall have got the European authentication certificate.

The power supply connects from the outdoor side. The connectingcable and the power cable are self-provided.

The parameter of connecting cable: H05RN-F 4G 0.75mm2 .

The paramter of Indoor and Outdoor unit:T3.15A/250VAC.If the fuse on PC board is broken, please change with the type.

DANGER!

Do not attempt to install this air conditioner by yourself.

This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.

When moving, consult authorized service personnel for disconnection and installation of the unit.

Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.

Do not insert fingers or objects into the outlet port or intake grills.

Do not start and stop air conditioner operation by connecting and disconnecting the power supply cord and so on.

Take care not to damage the power supply cord. If the supply card is damaged, it must be replaied by the manufacturer or authoried service agent in order to avoid a hazard.

In the event of a malfunction (burning smell, etc.), stop operation immediately, turn off the circuit breaker, and consult authorized service personnel.

3

Image 5
Contents Operation & Installation Manual Contents Disposal of the old air conditioner ERA EAASafety Precautions Safety Precautions Automatic Operation Features and FunctionsPress the AIR Flow Direction Horizontal SET button Press the AIR Flow Direction Vertical SET buttonRIGHT/LEFT For series 282, 362, 422, 482 Name of PartsFollowing four procedures are for series 282, 362, 422, 482 Cleaning and CareOperation and Performance Heating Performance Operation TipsLocation Installation of Indoor UnitSelecting the Mounting Position Indoor Unit Supension-bolt pitch should be as shown Install the room air conditioner as followsDrilling the Holes and Attaching the Suapension Bolts For HALF-CONCESLED Installation Flat washer Installing the Coupler Heat InsulationGood Badbad Installation of Indoor Unit Electrical Wiring Electrical Requirement FRESH-AIR Intake T N 1 2 Customer Guidance Followings are not problems Trouble ShootingPoor cooling Poor cooling or heatingRemarks SeriesError display For EAA series Haier Group