Haier AC282AFEAA, AC522AFERA, AC482AFEAA, AC362AFEAA Installation of Indoor Unit, Location

Page 13

Installation of Indoor Unit

Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions.

WARNING !

Please call dealer to install the air-conditioner.

Incorrect installation may cause water leaking, shock and fire hazard.

CAUTION !

Air-conditioner can't be installed in the envi- ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.

Installed electrical-leaking circuit breaker. It easily cause electrical shock without circuit breaker.

[Location]

Air-conditioner should be located in well-vented and easily-accessible place.

Air-conditioner should not be located in the following places:

(a)Places with machine oils or other oil vapours.

(b)Seaside with high salt content in the air.

(c)Near to hot spring with high content of sulfide gases.

(d)Area with frequent fluctuation of voltage e.g. factory, etc.

(e)In vehicles or ships.

(f)Kitchen with heavy oil vapour or humidity.

(g)Near to the machine emitting electric-magnetic waves.

(h)Places with acid, alkali vapuor.

TV, radio, acoustic appliances, etc. are at least 1 m far away to the indoor unit, outdoor unit, power

Connect earthing wire.

 

Earthing wire should not be con-

 

nected to the gas pipe, water pipe,

 

lightning rod or phone line, in-

 

correct earthing may cause shock.

Earthing

Use discharge pipe correctly to ensure efficient discharge.

Incorrect pipe use may cause water leaking.

supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created. As required, take measures against heavy snow.

[Wiring]

Air-conditioner should be equipped with special power supply wire.

[Operating noise]

Choose the following locations:

(a)Capable of supporting air-conditioner weight, don't increase operating noise and vibration.

(b)Hot vapour from outdoor unit outlet and ope- rating noise don't disturb neighbour.

No obstacles around the outdoor unit outlet.

11

Image 13
Contents Operation & Installation Manual Contents Disposal of the old air conditioner ERA EAASafety Precautions Safety Precautions Automatic Operation Features and FunctionsPress the AIR Flow Direction Horizontal SET button Press the AIR Flow Direction Vertical SET buttonRIGHT/LEFT For series 282, 362, 422, 482 Name of PartsFollowing four procedures are for series 282, 362, 422, 482 Cleaning and CareOperation and Performance Heating Performance Operation TipsLocation Installation of Indoor UnitSelecting the Mounting Position Indoor Unit Supension-bolt pitch should be as shown Install the room air conditioner as followsDrilling the Holes and Attaching the Suapension Bolts For HALF-CONCESLED Installation Flat washer Installing the Coupler Heat InsulationGood Badbad Installation of Indoor Unit Electrical Wiring Electrical Requirement FRESH-AIR Intake T N 1 2 Customer Guidance Followings are not problems Trouble ShootingPoor cooling Poor cooling or heatingRemarks SeriesError display For EAA series Haier Group