Haier AC282AFERA, AC522AFERA, AC482AFEAA Installing the Coupler Heat Insulation, Flat washer

Page 19

Installation of Indoor Unit

INSTALLING THE COUPLER HEAT INSULATION

After checking for gas leaks, insulate by wrapping insulation around the two parts (large and small) of the indoor unit coupling, using the coupler hest insulation.

After installling the coupler heat insulation, wrap both ends with vinyl tape so that there is no gap.

Secure both ends of the heat insulation material using nylon fasteners.

Fig. 10

Coupler heat insulation(large)

 

Coupler pipe (large)

Indoor unit

Coupler pipe (small)

 

 

Coupler heat insulation(small)

 

Nylon fastner (large)

Indoor unit

No gap

Coupler heat insulation

Nylon fastner (small)

When using an auxiliary pipe, make sure that the fastener used is insulated in the sane way.

Notice

When installing the unit on the floor, fix the four rubber base feet in the accessories on the bottom plate of the unit with four 4x16 screws and 4 flat washers,as the position in the figure.

A

A

 

 

4:1

rubber base foot

 

 

The bottom plate of the unit.

 

4x16 screw

flat washer

17

Image 19
Contents Operation & Installation Manual Contents Disposal of the old air conditioner ERA EAASafety Precautions Safety Precautions Automatic Operation Features and FunctionsPress the AIR Flow Direction Horizontal SET button Press the AIR Flow Direction Vertical SET buttonRIGHT/LEFT For series 282, 362, 422, 482 Name of PartsFollowing four procedures are for series 282, 362, 422, 482 Cleaning and CareOperation and Performance Heating Performance Operation TipsLocation Installation of Indoor UnitSelecting the Mounting Position Indoor Unit Supension-bolt pitch should be as shown Install the room air conditioner as followsDrilling the Holes and Attaching the Suapension Bolts For HALF-CONCESLED Installation Flat washer Installing the Coupler Heat InsulationGood Badbad Installation of Indoor Unit Electrical Wiring Electrical Requirement FRESH-AIR Intake T N 1 2 Customer Guidance Followings are not problems Trouble ShootingPoor cooling Poor cooling or heatingRemarks SeriesError display For EAA series Haier Group