Haier HSU-12HSA03/R2(DB), HSU-09HSA03/R2(DB) manual Fault explain

Page 25

Haier air conditioner

Edition: 20070116

in 7s resound 7 times.

b. Then operation as following program: Enter min capacity rated frequency operation; panel show cool status; have ration in communication.

Enter rated frequency operation; Panel show cool status; have ration in communication.

c. Exit condition Exit rated operate mode and enter remote control set status after received remote control signal.

.Fault explain

LCD fault code

Indoor unit fault code

 

 

Fault code

 

Contents

 

Remark

 

 

 

 

E1

 

Room temperature sensor fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E2

 

Heat exchange sensor fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E3

 

Total current Over Current

 

Use in split unit

 

 

 

E4

 

EEPROM error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E5

 

Cool icing

 

 

 

 

 

 

E6

 

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E7

 

Communication fault(between indoor and outdoor unit)

 

 

 

 

 

E8

 

communication between panel and indoor unit

 

 

 

 

 

 

E9

 

High load protection

 

 

 

 

 

 

E10

 

Humidity Sensor

 

 

 

 

 

 

E11

 

Stepping motor fault

 

 

 

 

 

 

E12

 

High voltage static electricity apparatus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E13

 

Power off moment

 

Heat overload

 

 

 

E14

 

Indoor fan motor fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E15

 

Central control fault

 

 

 

 

 

 

E16

 

High voltage electrostatic dust collection fault

 

 

 

 

 

 

E17

 

reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E18

 

reserved

 

 

 

 

 

 

E19

 

reserved

 

 

 

 

Outdoor unit fault code

 

 

 

 

 

 

 

 

 

 

 

 

Fault code

 

Contents

Remark

 

 

 

F1

 

Module fault (overheat, over current, short circuit)

 

 

 

 

 

 

 

 

 

 

 

 

 

F2

 

No load

 

 

 

 

 

F3

 

Communication fault

 

 

 

 

 

 

 

 

 

 

 

F4

 

Compressor overheat

Ventilation

temperature

 

 

 

 

 

protection

 

 

 

F5

 

Total current Over Current

 

 

 

 

 

 

 

- 25 -

 

 

 

 

Image 25
Contents Haier air conditioner Domestic Air conditionerContents Related Publications General informationMain Specification Product FeaturesModel HSU-12HSA03/R2DB Specification Edition Chip pin definition Scope of ApplicationII. Temperature adjustment function Preset temperature correction When frequency increase to holding frequencyDeviation Control the temperature the areaControl frequency in the same area Air capacity limited DefrostHeat operation Indoor fan motor controlHaier air conditioner Dry operation Cool operationEnhanced heat Enhanced operationEnhanced Cool Silence operation Timer operatingFresh air Automation operating mode Timer ON/OFFSleep operating Automatic operationRunning-in Full-automation operationLow load protection controlling Low load protection control High load protection controlEeprom control Low temperature treatment in the heat modePower failure compensation Error list recordSpecial function Indoor unit single operatingRating cool Rating operatingFault explain Emergency switch Vertical swing Air deflector controlSetting position range Cool/dry +DLHUDLUFRQGLWLRQHUGLWLRQ +RULRQWDOVZLQJ Room temperature sensor Thermistor resistance chart10.76 10.31 Indoor pipe sensor&outdoor ambient sensor, defrosting sensor Haier air conditioner Haier air conditioner Temperature Haier air conditioner Haier air conditioner 111 Haier air conditioner Trouble shooting System may have been over or under Heat-exchange sensor failure Room temperature sensor failureYes CN9 ‡ ‡ 1R ‡  Malfunction Unsolved F11 The malfunction of the compressor’ rotor circuitF4 Overheat protection for exhaust temperature F22 AC electricity protection F1 The protection of IPM E9 High work-intense protection F12 Outdoor Eeprom error E4 Indoor Eeprom errorYES Indoor fan motor malfunctionF3 Communication fault between the IPM and outdoor PCB F19 Power voltage is too high or low Yes High drop and long pipe capacity modification curves Performance curves diagramCooling value Temperature table Cooling capacity-temperature curvesHSU-09HSA03/R2DB HSU-12HSA03/R2DB Heating capacity Temp. curves Heating capacity-temperature curvesHaier air conditioner Air outlet temp. Ambient temp. table Air outlet temp.-ambient temperature curves HSU-09HSA03/R2DB10.15 Cooling discharge pressure table Cooling discharge pressure curves HSU-09HSA03/R2DBHaier air conditioner Cooling suction pressure table Cooling suction pressure curves HSU-09HSA03/R2DBHaier air conditioner Heating discharge pressure table Heating discharge pressure curves HSU-09HSA03/R2DBHaier air conditioner Heating suction pressure table Heating suction pressure curves HSU-09HSA03/R2DB600 Sensible cooling value Temperature table Sensible cooling value-temperature curves HSU-09HSA03/R2DBHSU-12HSA03/R2DB Power consumption value Temp. table Power consumption-temp. Curves HSU-09HSA03/R2DB18/12 843 969 1152 1348 1564 1687 1820 1972 18/14 855 Noise curves HSU-09HSA03/R2DB Haier air conditionerEdition Compressor performance curvesHSU-09HSA03/R2DB HSU-12HSA03/R2DB Compressor C-6RZ092H1AWiring diagram ,$*5$0228722581,7 Circuit Diagram Indoor unit Outdoor Unit Installation Manual of Room Air Conditioner Selection of Installation Place Outdoor Unit Indoor unit Installation of the Indoor Unit Drawing of pipe When connecting the cable after installing the indoor unit Outdoor unit Purging MethodTo use vacuum pump Power Source Installation Haier air conditioner