Haier HSU-09HSA03/R2(DB), HSU-12HSA03/R2(DB) manual Specification

Page 6

Haier air conditioner

Edition: 20070116

2. Specification

 

Item

Unit

HSU-09HSA03

HSU-12HSA03

 

/R2(DB)

/R2(DB)

 

 

 

 

 

 

 

 

Power

 

PH, V, Hz

1, 230, 50

1,230,50

 

 

 

 

 

Climate Type

 

 

T1

T1

Starting Current

 

A

10

12

 

 

 

 

 

 

Cooling Capacity

W

2400

3300

 

Rated Power

W

680

1078

 

 

 

 

 

Cooling

Rated Current

A

3.50

4.9

Max Power

W

870

1350

 

 

 

 

 

 

 

Max Current

A

3.8

6.0

 

EER

W/W

3.53

3.06

 

 

 

 

 

 

Heating Capacity

W

2650

3600

 

Rated Power

W

730

1230

 

 

 

 

 

Heating

Rated Current

A

3.8

5.4

Max Power

W

1100

1480

 

 

Max Current

A

4.4

6.8

 

 

 

 

 

 

EER

W/W

3.63

2.93

Operating temp.

Cooling

 

18~46

18~46

range

 

 

 

 

Heating

 

-15~24

-15~24

 

H

rpm

1150

1300

Indoor fan Velocity

 

 

 

 

M

rpm

950

950

 

L

rpm

740

740

 

 

 

 

 

Outdoor fan Velocity

 

rpm

710

800

Indoor Air Volume (High)

m3

400

450

Max. pressure at warm side

MPa

4.15

4.15

Moisture Removal

 

10-3m3/h

0.83

1.2

Noise Level

Indoor (H/M/L)

dB(A)

42/40/38

42/40/38

 

 

 

 

Outdoor

dB(A)

48

52

 

Indoor Weight

Net

Kg

8.6

8.6

 

 

 

 

Gross

Kg

10.8

10.8

 

Outdoor Weight

Net

Kg

31

33

 

 

 

 

Gross

Kg

34

36

 

 

 

 

 

 

Indoor Dimension

Net

mm

760×182×285

760×182×285

Package

mm

837×282×312

837×282×312

 

 

 

 

 

 

Outdoor Dimension

Net

mm

780×245×540

780×245×540

 

 

 

 

Package

mm

790×366×484

790×366×484

 

 

Manufacture

 

TOSHIBA

SANYO

Compressor

 

 

 

 

Type

 

DA89X1C-20FZ

C-6RZ092H1A

 

 

 

 

 

 

Oil Charge

ml

370

320

 

 

- 6 -

 

 

Image 6
Contents Domestic Air conditioner Haier air conditionerContents General information Related PublicationsProduct Features Main SpecificationModel HSU-12HSA03/R2DB Specification Edition Scope of Application Chip pin definitionII. Temperature adjustment function When frequency increase to holding frequency Preset temperature correctionControl the temperature the area DeviationControl frequency in the same area Defrost Air capacity limitedIndoor fan motor control Heat operationHaier air conditioner Cool operation Dry operationEnhanced operation Enhanced heatEnhanced Cool Timer operating Silence operationFresh air Sleep operating Timer ON/OFFAutomation operating mode Automatic operationFull-automation operation Running-inLow load protection controlling High load protection control Low load protection controlLow temperature treatment in the heat mode Eeprom controlSpecial function Error list recordPower failure compensation Indoor unit single operatingRating operating Rating coolFault explain Emergency switch Air deflector control Vertical swingSetting position range Cool/dry +DLHUDLUFRQGLWLRQHUGLWLRQ +RULRQWDOVZLQJ Thermistor resistance chart Room temperature sensor10.76 10.31 Indoor pipe sensor&outdoor ambient sensor, defrosting sensor Haier air conditioner Haier air conditioner Temperature Haier air conditioner Haier air conditioner 111 Haier air conditioner Trouble shooting System may have been over or under Room temperature sensor failure Heat-exchange sensor failureYes CN9 ‡ ‡ 1R ‡  F11 The malfunction of the compressor’ rotor circuit Malfunction UnsolvedF4 Overheat protection for exhaust temperature F22 AC electricity protection F1 The protection of IPM E9 High work-intense protection E4 Indoor Eeprom error F12 Outdoor Eeprom errorIndoor fan motor malfunction YESF3 Communication fault between the IPM and outdoor PCB F19 Power voltage is too high or low Yes Performance curves diagram High drop and long pipe capacity modification curvesCooling capacity-temperature curves Cooling value Temperature tableHSU-09HSA03/R2DB HSU-12HSA03/R2DB Heating capacity-temperature curves Heating capacity Temp. curvesHaier air conditioner Air outlet temp.-ambient temperature curves HSU-09HSA03/R2DB Air outlet temp. Ambient temp. table10.15 Cooling discharge pressure curves HSU-09HSA03/R2DB Cooling discharge pressure tableHaier air conditioner Cooling suction pressure curves HSU-09HSA03/R2DB Cooling suction pressure tableHaier air conditioner Heating discharge pressure curves HSU-09HSA03/R2DB Heating discharge pressure tableHaier air conditioner Heating suction pressure curves HSU-09HSA03/R2DB Heating suction pressure table600 Sensible cooling value-temperature curves HSU-09HSA03/R2DB Sensible cooling value Temperature tableHSU-12HSA03/R2DB Power consumption-temp. Curves HSU-09HSA03/R2DB Power consumption value Temp. table18/12 843 969 1152 1348 1564 1687 1820 1972 18/14 855 Noise curves HSU-09HSA03/R2DB Compressor performance curves Haier air conditionerEditionHSU-09HSA03/R2DB Compressor C-6RZ092H1A HSU-12HSA03/R2DBWiring diagram ,$*5$0228722581,7 Circuit Diagram Indoor unit Outdoor Unit Installation Manual of Room Air Conditioner Selection of Installation Place Outdoor Unit Indoor unit Installation of the Indoor Unit Drawing of pipe When connecting the cable after installing the indoor unit Outdoor unit Purging MethodTo use vacuum pump Power Source Installation Haier air conditioner