Haier air conditioner

Edition: 20070116

3. Electrical control

. Scope of Application

This specification use for HSU-09/12HSA03/R2 DB frequency conversion air condition are manufactured by Haier air condition parent company. "Setting value" (express in parameter) in this specification means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter table].

1. Chip pin definition

This controller adopts MOTROLA MC68HC908 AB32; Chip each pin definition as following:

1

PTC4

door switch

2

IRQ

 

3

RST

over-zero detection

 

 

 

4

PTF0/TACH2

remote control receiving

5

PTF1/TACH3

SDA

 

 

 

6

PTF2/TBCH2

SCL

7

PTF3/TBCH3

Buzzer

 

 

 

8

PTF4/TBCH0

Swing stepping motor A

9

NC

 

10

PTF7

Swing stepping motor D

11

PTF5/TBCH1

Swing stepping motor B

12

PTF6

Swing stepping motor C

13

PTE0/TXD

network output

 

 

 

14

PTE1/RXD

network output

15

PTE2/TACH0

PG feedback

 

 

 

16

PTE3/TACH1

PG output

17

PTE4/SS

fresh air

18

PTE5/MISO

negative ion output

 

 

 

19

PTE6/MOSI

self check/ decrease time

20

PTE7/SPSCK

empty

21

VSS

GND

22

VDD

VCC

23

PTG0/KBD0

ultraviolet ray A

24

PTG1/KBD1

empty

 

 

 

25

PTG2/KBD2

empty

26

PA0 selection panel 1

sliding stepping motor A

 

 

 

27

PA1 high/low drive model

sliding stepping motor B

28

PA2 large/small model

sliding stepping motor C

 

 

 

29

PA3 A/B code selection

sliding stepping motor D

30

PA4 panel selection 2

pushup stepping motor A

31

PA5

pushup stepping motor B

 

 

- 8 -

Image 8
Contents Domestic Air conditioner Haier air conditionerContents General information Related PublicationsProduct Features Main SpecificationModel HSU-12HSA03/R2DB Specification Edition Scope of Application Chip pin definitionII. Temperature adjustment function When frequency increase to holding frequency Preset temperature correctionControl the temperature the area DeviationControl frequency in the same area Defrost Air capacity limitedIndoor fan motor control Heat operationHaier air conditioner Cool operation Dry operationEnhanced Cool Enhanced operationEnhanced heat Fresh air Timer operatingSilence operation Timer ON/OFF Automation operating modeSleep operating Automatic operationLow load protection controlling Full-automation operationRunning-in High load protection control Low load protection controlLow temperature treatment in the heat mode Eeprom controlError list record Power failure compensationSpecial function Indoor unit single operatingRating operating Rating coolFault explain Emergency switch Air deflector control Vertical swingSetting position range Cool/dry +DLHUDLUFRQGLWLRQHUGLWLRQ +RULRQWDOVZLQJ Thermistor resistance chart Room temperature sensor10.76 10.31 Indoor pipe sensor&outdoor ambient sensor, defrosting sensor Haier air conditioner Haier air conditioner Temperature Haier air conditioner Haier air conditioner 111 Haier air conditioner Trouble shooting System may have been over or under Yes Room temperature sensor failureHeat-exchange sensor failure CN9 ‡ ‡ 1R ‡  F11 The malfunction of the compressor’ rotor circuit Malfunction UnsolvedF4 Overheat protection for exhaust temperature F22 AC electricity protection F1 The protection of IPM E9 High work-intense protection E4 Indoor Eeprom error F12 Outdoor Eeprom errorIndoor fan motor malfunction YESF3 Communication fault between the IPM and outdoor PCB F19 Power voltage is too high or low Yes Performance curves diagram High drop and long pipe capacity modification curvesHSU-09HSA03/R2DB Cooling capacity-temperature curvesCooling value Temperature table HSU-12HSA03/R2DB Heating capacity-temperature curves Heating capacity Temp. curvesHaier air conditioner Air outlet temp.-ambient temperature curves HSU-09HSA03/R2DB Air outlet temp. Ambient temp. table10.15 Cooling discharge pressure curves HSU-09HSA03/R2DB Cooling discharge pressure tableHaier air conditioner Cooling suction pressure curves HSU-09HSA03/R2DB Cooling suction pressure tableHaier air conditioner Heating discharge pressure curves HSU-09HSA03/R2DB Heating discharge pressure tableHaier air conditioner Heating suction pressure curves HSU-09HSA03/R2DB Heating suction pressure table600 Sensible cooling value-temperature curves HSU-09HSA03/R2DB Sensible cooling value Temperature tableHSU-12HSA03/R2DB Power consumption-temp. Curves HSU-09HSA03/R2DB Power consumption value Temp. table18/12 843 969 1152 1348 1564 1687 1820 1972 18/14 855 Noise curves HSU-09HSA03/R2DB HSU-09HSA03/R2DB Compressor performance curvesHaier air conditionerEdition Compressor C-6RZ092H1A HSU-12HSA03/R2DBWiring diagram ,$*5$0228722581,7 Circuit Diagram Indoor unit Outdoor Unit Installation Manual of Room Air Conditioner Selection of Installation Place Outdoor Unit Indoor unit Installation of the Indoor Unit Drawing of pipe When connecting the cable after installing the indoor unit Outdoor unit Purging MethodTo use vacuum pump Power Source Installation Haier air conditioner