Haier HSU-12HSA03/R2(DB), HSU-09HSA03/R2(DB) manual Temperature

Page 35

Haier air conditioner

Edition: 20070116

OUTDOOR discharge -temperature sensor

 

 

 

 

R80 =50K ±3%

 

 

 

 

B25/80

=4450K±3%

temperature

max Resistance

normal, Resistance

min Resistance

 

t

 

 

 

 

 

 

 

( )

(Kȍ)

(Kȍ)

(Kȍ)

 

( )

 

 

 

 

 

 

 

-30

14646.0505

12061.7438

9924.4999

-2.96

 

2.45

 

 

 

 

 

 

-29

13654.1707

11267.8730

9290.2526

-2.95

 

2.44

 

 

 

 

 

 

-28

12735.8378

10531.3695

8700.6388

-2.93

 

2.44

 

 

 

 

 

 

-27

11885.1336

9847.7240

8152.2338

-2.92

 

2.43

 

 

 

 

 

 

-26

11096.6531

9212.8101

7641.8972

-2.91

 

2.42

 

 

 

 

 

 

-25

10365.4565

8622.8491

7166.7474

-2.90

 

2.42

 

 

 

 

 

 

-24

9687.0270

8074.3787

6724.1389

-2.88

 

2.41

 

 

 

 

 

 

-23

9057.2314

7564.2244

6311.6413

-2.87

 

2.41

 

 

 

 

 

 

-22

8472.2852

7089.4741

5927.0206

-2.86

 

2.40

 

 

 

 

 

 

-21

7928.7217

6647.4547

5568.2222

-2.84

 

2.39

 

 

 

 

 

 

-20

7423.3626

6235.7109

5233.3554

-2.83

 

2.39

 

 

 

 

 

 

-19

6953.2930

5851.9864

4920.6791

-2.82

 

2.38

 

 

 

 

 

 

-18

6515.8375

5494.2064

4628.5894

-2.80

 

2.37

 

 

 

 

 

 

-17

6108.5393

5160.4621

4355.6078

-2.79

 

2.37

 

 

 

 

 

 

-16

5729.1413

4848.9963

4100.3708

-2.77

 

2.36

 

 

 

 

 

 

-15

5375.5683

4558.1906

3861.6201

-2.76

 

2.35

 

 

 

 

 

 

-14

5045.9114

4286.5535

3638.1938

-2.75

 

2.34

 

 

 

 

 

 

-13

4738.4141

4032.7098

3429.0191

-2.73

 

2.34

 

 

 

 

 

 

-12

4451.4586

3795.3910

3233.1039

-2.72

 

2.33

 

 

 

 

 

 

-11

4183.5548

3573.4260

3049.5312

-2.70

 

2.32

 

 

 

 

 

 

-10

3933.3289

3365.7336

2877.4527

-2.69

 

2.31

 

 

 

 

 

 

-9

3699.5139

3171.3148

2716.0828

-2.67

 

2.30

 

 

 

 

 

 

-8

3480.9407

2989.2460

2564.6945

-2.66

 

2.29

 

 

 

 

 

 

-7

3276.5302

2818.6731

2422.6139

-2.64

 

2.28

 

 

 

 

 

 

-6

3085.2854

2658.8058

2289.2164

-2.63

 

2.28

 

 

 

 

 

 

-5

2906.2851

2508.9126

2163.9230

-2.61

 

2.27

 

 

 

 

 

 

-4

2738.6777

2368.3158

2046.1961

-2.60

 

2.26

 

 

 

 

 

 

-3

2581.6752

2236.3876

1935.5371

-2.58

 

2.25

 

 

 

 

 

 

-2

2434.5487

2112.5459

1831.4826

-2.56

 

2.24

 

 

 

 

 

 

-1

2296.6230

1996.2509

1733.6024

-2.55

 

2.23

 

 

 

 

 

 

0

2167.2730

1887.0018

1641.4966

-2.53

 

2.22

 

 

 

 

 

 

 

 

 

- 35 -

 

 

 

 

Image 35
Contents Haier air conditioner Domestic Air conditionerContents Related Publications General informationMain Specification Product FeaturesModel HSU-12HSA03/R2DB Specification Edition Chip pin definition Scope of ApplicationII. Temperature adjustment function Preset temperature correction When frequency increase to holding frequencyDeviation Control the temperature the areaControl frequency in the same area Air capacity limited DefrostHeat operation Indoor fan motor controlHaier air conditioner Dry operation Cool operationEnhanced Cool Enhanced operationEnhanced heat Fresh air Timer operatingSilence operation Automatic operation Timer ON/OFFAutomation operating mode Sleep operatingLow load protection controlling Full-automation operationRunning-in Low load protection control High load protection controlEeprom control Low temperature treatment in the heat modeIndoor unit single operating Error list recordPower failure compensation Special functionRating cool Rating operatingFault explain Emergency switch Vertical swing Air deflector controlSetting position range Cool/dry +DLHUDLUFRQGLWLRQHUGLWLRQ +RULRQWDOVZLQJ Room temperature sensor Thermistor resistance chart10.76 10.31 Indoor pipe sensor&outdoor ambient sensor, defrosting sensor Haier air conditioner Haier air conditioner Temperature Haier air conditioner Haier air conditioner 111 Haier air conditioner Trouble shooting System may have been over or under Yes Room temperature sensor failureHeat-exchange sensor failure CN9 ‡ ‡ 1R ‡  Malfunction Unsolved F11 The malfunction of the compressor’ rotor circuitF4 Overheat protection for exhaust temperature F22 AC electricity protection F1 The protection of IPM E9 High work-intense protection F12 Outdoor Eeprom error E4 Indoor Eeprom errorYES Indoor fan motor malfunctionF3 Communication fault between the IPM and outdoor PCB F19 Power voltage is too high or low Yes High drop and long pipe capacity modification curves Performance curves diagramHSU-09HSA03/R2DB Cooling capacity-temperature curvesCooling value Temperature table HSU-12HSA03/R2DB Heating capacity Temp. curves Heating capacity-temperature curvesHaier air conditioner Air outlet temp. Ambient temp. table Air outlet temp.-ambient temperature curves HSU-09HSA03/R2DB10.15 Cooling discharge pressure table Cooling discharge pressure curves HSU-09HSA03/R2DBHaier air conditioner Cooling suction pressure table Cooling suction pressure curves HSU-09HSA03/R2DBHaier air conditioner Heating discharge pressure table Heating discharge pressure curves HSU-09HSA03/R2DBHaier air conditioner Heating suction pressure table Heating suction pressure curves HSU-09HSA03/R2DB600 Sensible cooling value Temperature table Sensible cooling value-temperature curves HSU-09HSA03/R2DBHSU-12HSA03/R2DB Power consumption value Temp. table Power consumption-temp. Curves HSU-09HSA03/R2DB18/12 843 969 1152 1348 1564 1687 1820 1972 18/14 855 Noise curves HSU-09HSA03/R2DB HSU-09HSA03/R2DB Compressor performance curvesHaier air conditionerEdition HSU-12HSA03/R2DB Compressor C-6RZ092H1AWiring diagram ,$*5$0228722581,7 Circuit Diagram Indoor unit Outdoor Unit Installation Manual of Room Air Conditioner Selection of Installation Place Outdoor Unit Indoor unit Installation of the Indoor Unit Drawing of pipe When connecting the cable after installing the indoor unit Outdoor unit Purging MethodTo use vacuum pump Power Source Installation Haier air conditioner