Hitachi EP-A7000 instruction manual To Prevent Floor Scratches or Wall Stains

Page 6

Safety Precautions (Continued)

CAUTION

Miscellaneous

Securely hold the grip when carrying air purifier.

Damaging or dropping it may cause injury. When you attach or detach the panel and water tank, do it slowly and securely. Otherwise, it may cause water leakage or injury of fi ngers pinched.

Use dry cell batteries properly after reading the precautions on them. Renew water in the water tank daily using tap water and clean the tank periodically according to the instructions given in the “Cleaning” section of this manual. Continued use without cleaning may allow propagation of molds or bacteria due to dirt and water scale, producing unpleasant odor. In rare cases, they may cause a health risk to those who are hyperactive. In such a case, please seek medical advice. Only use fresh tap water

Otherwise, it may cause deformation or degeneration of parts, unit failure or unpleasant smell due to propagation of molds or bacteria. Do not use hot water (over 40ºC), water through water purifi er, alkali ion water, mineral water, well water or the like. Do not put organic solvent or chemicals into the water tank.

Do not drink, or let drink, water in the water tank and water tray.

It may cause a health threat.

Do not leave the detached water tank with its cap closed.

Inner pressure of the tank changes according to ambient temperature change and may cause water leakage or injury due to deformation or damage.

Use a genuine filter for the Hitachi Air Purifier. Other fi lters may cause unit failure.

Do not operate the unit when using fumigating (smoking) type insecticide.

Using such insecticide will cause chemicals to accumulate in the unit and to be emitted by subsequent operation, which can be harmful to heath.

After using insecticide, ventilate the room well before running the purifi er. Do not allow water to freeze.

Water tank may be damaged, causing a risk of electric shock and unit failure. Whenever freezing of water is anticipated, drain the water tank and water tray.

Do not use the purifier having water leakage trouble.

It may cause electric shock. When water leaks, unplug the power cord from AC outlet and ask for repair. Do not carry the purifier with its water tank filled.

It may cause water leakage or injury. If you carry the purifi er with fi lled water tank, level of water in the tray will rise and cause the water to overfl ow when operated.

Drain the water tank and water tray

rst, and set them on the unit before carrying.

Do not tip over or drop the water tank when it is filled.

It may cause injury or result in deformed or damaged tank. Hold the tank securely when you fi ll it with water.

Do not look into the indicator. It may cause injury to your eyes.

To Prevent Floor Scratches or Wall Stains

During Cleaning / Place of Use

During cleaning, lay a soft cloth on the floor and place the purifier and detached components (panel, water tank, water tray, etc.) on it. Otherwise, it may cause scratches on the fl oor.

When you pull out the water tray, be careful not to scratch the floor with bottom of the tray.

Do not use the air purifier near the wall that cannot be scrubbed such as cloth-covered white wall.

The air purifi er will take in the surrounding air and may produce local stains.

E-6

Image 6
Contents EP-A7000 Features / Name of Each Component / Accessories Operation Buttons and Indicators Safety Precautions Meanings of SymbolsDefinition of each indication Water Tank, Water Tray and Humidifying Filter To Prevent Floor Scratches or Wall Stains Do not run with filter detached Do not subject remote controller to impactDo not directly fan animals and plants Do not subject water tank to impactReinstall the panel on the unit Install the Deodorizing filterInstall the dust filter on the unit Preparations for OperationGently remove the water tank Inserting Batteries into Remote ControllerInsert batteries and close the cover Set the water tank into the water tank holderInstallation Air Purify mode indicator is lit in greenRemote controller operation is accepted even in this state Pollen Installation Using Remote ControllerGreen OrangeAirflow rate changes in the following sequence Using Remote ControllerAirflow level indicator comes on Silent Medium High Blinking MaxWill continue for about 5 minutes Off-timer 4 hours is setOperation with Max airflow Operation will stop approxAir Sensor Using the Control on PurifierMemory Function Odor SensorDust sensor Humidity SensorAuto Detection Factory setting is Medium Each operation modeSensor sensitivity can be adjusted in 3-step fashion Press buttonUseful Feature Indicators are dimmedEvery time you press button, Set and Cancel will alternate Cleaning When the Clean Humidifying Filter Indicator Comes OnWater Tank Guide for cleaning Daily Humidifying Filter Guide for cleaning Once a monthCleaning Do not dispose of the humidifying filter case Water Tray / Tray Cover Guide for cleaning Once a monthReplacing Humidifying Filter Wipe off water and assembleRemove the panel. P.E-8 Remove the pre-filter Pre-filterGuide for cleaning Once a monthClean the pre-filter Reattach the pre-filterPurifier Body Guide for cleaning Once a month Dust sensor Cleaning guide every 3-6 monthsFilter Replacement Replacement IntervalPrecautions on Filter Handling Use a genuine filter for the Hitachi Air Purifier Replacing the FilterRemove the panel and the pre-filter Remove the used filter It may also be a cause of malfunctionTroubleshooting Guide Alert DisplayWater leaks Indicator is dim Clean Humidifying Filter indicator does not go offIs there anything nearby that the odor sensor might sense? Following Conditions Are Normal 10kg Length of power cord Approx .8m Deodorizing filterApplicable floor space 50m