EAW DSA230i, DSA250i owner manual Mounting Height

Page 29

5.6.6 MOUNTING HEIGHT

The elevation entered into DSAPilot refers to distance from the bottom of the module’s enclosure or the bottom of the lowest module’s enclosure in a multi-module cluster to the floor below. Thus, the mounting height is the same as the elevation in DSAPilot.

5.6.7 WALL BRACKET INSTALLATION

DANGER: ONLY PERSONS WITH THE KNOWLEDGE OF PROPER HARDWARE AND INSTALLATION TECHNIQUES REQUIRED SHOULD ATTEMPT TO INSTALL DSAi SERIES MODULES OVERHEAD. FAILURE TO FOLLOW THIS PRECAUTION MAY RESULT IN DAMAGE TO THE EQUIPMENT, INJURY, OR DEATH.

The supplied Wall Brackets are designed for attachment of the module enclosure to a wall or other vertical surface. Ensure both the hardware used to attach to structure and the structure itself are capable of supporting the load with a design factor that meets applicable building codes.

See Mechanical Drawings in Chapter 9 for weights.

Using the supplied Wall Bracket Mounting Template or exact measurements, locate the four mounting points required to attach each supplied Wall Bracket to the supporting structure. Mounting templates are provided on the shipping-carton and CD-ROM. A bracket template is shown in chapter 9. Ensure that these mounting points are plumb and square to each other so the enclosure will be exactly vertical when installed. Out of plumb and/or square Wall Brackets can prevent proper engagement with the Enclosure Brackets.

Critical Dimensions:

1.Spacing between the Wall Brackets for a single module must be within 0.1 in / 3 mm of the dimensions in Figure 5.6.7a. In order to lift a module onto its wall brackets, spacing between the top wall

bracket and ceiling, or other overhead obstruction, must be 8.5 inches minimum.

NOTE: 8.5 inches allows only 0.25 inches extra clearance.

ACOUSTICAL

REFERRENCE

POINTC L

("ON AXIS" )

MOUNTING

HEIGHT

FLOOR

Figure 5.6.6 Mounting Height

8.5 in MINIMUM TO CEILING

DSA250i

DSA230i

38.1 in

23.9 in

968.3

mm

 

606.3 mm

 

 

Figure 5.6.7a Wall Bracket

2.Spacing between the Wall Brackets for modules mounted over- under fashion must be 4.9 inches.

3.Spacing between the Wall Brackets for modules mounted side by side must be 5.4 inches.

5.4 in

136.6

mm

 

Figure 5.6.7c Side-By-Side Spacing

4.9 in

123.9

mm

 

Figure 5.6.7b Over-Under Spacing

25

Image 29
Contents Page Safety Precautions Read this First Precauciones DE Seguridad LEA Esto Primero EC Declaration of Conformity Contents Page Introduction ContentsUnpacking Shipping DamageChapter Audio Signal ConnectionReturning Products to EAW Quick StartComputer Control Connection Daisy Chaining Audio and Computer Signal Between ModulesAC Mains Installation Signal End / Power End Physical InstallationSystem Overview Signal ProcessingDescription 4 DSAi Block Diagrams FeaturesElectronic Engineering Design Applications4a Angled Radiation Pattern Low Frequency Performance DSAPilotComparison to Traditional Products Designing DSAi SystemsAnalog Audio and EIA-485 Computer Control Installation2 Audio a & Audio B Recommended Conductor Gauge AWG to 18 AWG / 0.2 mm to 1 mm CobraNet Audio and Computer Control 3 Basic CobraNet DiagramCabling Fault Detect Supervisory Monitoring 3a Single DSAi Fault on 2 PowerCon Plug AC Mains Power Connection4 Fuse Grounding2 Signal End / Power End 3 DSAi Cluster Configurations 4a Wall Mounted 6 Mounting Height Lift the enclosure onto the structure-mounted Wall Brackets Initial Set-Up Acoustical InstallationOperational Functions OperationSignal Monitoring Normal Operation Operational Check ListOperational ‘DOS’ and ‘DONTS’ Warranty Maintenance and ServiceService Items How to Contact EAWAppendices Inspections and MaintenanceDSA250i Only TroubleshootingEIA-485 CobraNet EIA-485 Network NotesSupport For CobraNet Support For EthernetDSAi Connections 3a EIA-485 Example 5c Example One path was to the EIA-485 port. So when B responds 6c Example Right Side Back Mechanical DrawingsRight Side Wall Bracket Full Scale