Chapter 6 Operation
This section provides details about DSAi operation. The general operation of a DSAi module is similar to the operation of most loudspeakers. Initial system
These operation instructions assume that the module has ac mains, audio signal, and computer control lines properly connected, and that they are passing signals correctly.
6.1 Operational Functions
There are several, unique functions that affect and enhance operation. These include Power Management, LED Indicator, and signal Monitoring.
6.1.1 POWER MANAGEMENT
The Power Management feature is a power saving function that improves energy efficiency. This feature automatically puts the DSAi amplifiers into
Enable or disable this function using DSAPilot. If enabled, the period of time the input signal must be absent before entering
6.1.2 LED INDICATOR
The LED Indicator located on the front of a DSAi module at the “Signal End” can be set to indicate the status of several operating conditions. Enable or disable each indication using DSAPilot. The actual conditions monitored by the LED are not affected by enabling or disabling the LED indication.
1Initialization: The LED on the “Signal End” will flash rapidly for about 3 seconds when first powered on. This is normal and indicates the electronics are being initialized. The LED should then go off. This indication is permanently enabled.
2.Input Clip: If this indication is enabled, random flashing shows that the audio input signal is clipping the A to D converters at the input. To correct this condition, reduce the input signal level at the source. Because the input gain is after the A to D converters, the DSAi input gain adjustment will have no effect on this condition.
28