Figure 3.1 DSA230i & DSA250i

AUDIO

AUDIO +

SHIELD

Figure 3.2 Audio Connector

2.3 Returning Products to EAW

If the loudspeaker must be returned to EAW, contact the EAW Service Department for a Return Authorization (See Chapter 7). Use the original shipping carton and packing materials. If the shipping carton is lost or damaged, contact EAW for a new carton, for which there will be a small charge. EAW will not be responsible for damage caused by inadequate packing when returning the loudspeaker for service.

All units returned must have a factory Return Authorization Number. Any units received without a Return Authorization Number assigned and written prominently on the outside of the carton will be refused.

Chapter 3

Quick Start

This section provides basic installation requirements. Refer to Chapter 5 for detailed instructions.

Module refers to either a DSA230i or DSA250i loudspeaker.

Cluster refers to any of the permissible arrangements of single or multiple DSA230i or DSA250i modules as defined in DSAPilot. Whether they consist of a single or multiple modules, all DSAi clusters function as a single loudspeaker.

3.1 Description

DSAi modules are variable directivity, self-powered line arrays. EAW’s easy-to-use DSAPilot provides computer control for the module’s vertical beamwidth pattern. This allows customizing the coverage on-site to fit the application. Modules are controlled via standard EIA-485* or optional CobraNet™/Ethernet networking.

*Also known as RS-485 (Recommended Standard 485)

Model DSA250i is a full range module. Model DSA230i can be employed as a voice-only module or as low frequency module to supplement a DSA250i’s low frequency output and pattern control.

3.2 Audio Signal Connection

NOTE: Using DSAPilot, the two input channels may be summed to mono, used separately, or set up for a priority override function: Audio B overrides Audio A. Equalization, compression, and level are separately adjustable for each input. Overall signal delay for each module and cluster is also provided.

Audio A and B (each): 2-conductor shielded audio cable/supplied Phoenix Contact terminal block plug

4

Image 8
Contents Page Safety Precautions Read this First Precauciones DE Seguridad LEA Esto Primero EC Declaration of Conformity Contents Page Contents IntroductionUnpacking Shipping DamageAudio Signal Connection ChapterReturning Products to EAW Quick StartComputer Control Connection Daisy Chaining Audio and Computer Signal Between ModulesAC Mains Installation Physical Installation Signal End / Power EndSystem Overview Signal ProcessingDescription Features 4 DSAi Block DiagramsElectronic Applications Engineering Design4a Angled Radiation Pattern DSAPilot Low Frequency PerformanceComparison to Traditional Products Designing DSAi SystemsInstallation Analog Audio and EIA-485 Computer Control2 Audio a & Audio B Recommended Conductor Gauge AWG to 18 AWG / 0.2 mm to 1 mm 3 Basic CobraNet Diagram CobraNet Audio and Computer ControlCabling Fault Detect Supervisory Monitoring 3a Single DSAi Fault on AC Mains Power Connection 2 PowerCon PlugGrounding 4 Fuse2 Signal End / Power End 3 DSAi Cluster Configurations 4a Wall Mounted 6 Mounting Height Lift the enclosure onto the structure-mounted Wall Brackets Acoustical Installation Initial Set-UpOperation Operational FunctionsSignal Monitoring Operational Check List Normal OperationOperational ‘DOS’ and ‘DONTS’ Maintenance and Service WarrantyService Items How to Contact EAWInspections and Maintenance AppendicesTroubleshooting DSA250i OnlyEIA-485 EIA-485 Network Notes CobraNetSupport For Ethernet Support For CobraNetDSAi Connections 3a EIA-485 Example 5c Example One path was to the EIA-485 port. So when B responds 6c Example Mechanical Drawings Right Side BackRight Side Full Scale Wall Bracket