EAW DSA230i, DSA250i owner manual EIA-485

Page 39

Coverage is incorrect

Improper set-up

Using DSAPilot, ensure the

 

 

desired beamwidth and aiming

 

 

angle are correct.

Coverage is incorrect

Module upside down

Using DSAPilot to active the

 

 

module’s LED indicator, ensure

 

 

the up/down enclosure orientation

 

 

is correct for the application.

Distorted sound

Failed internal component(s)

Using DSAPilot’s Service

 

 

Mode, check the operation of each

 

 

amplifier and driver.

Distorted sound

Excessive levels

Using DSAPilot, monitor the

 

 

DSAi signal path to check for

 

 

clipping at all monitoring points.

Distorted sound

Bad input signal

Use a substitute amplifier and

 

 

module to check the quality

 

 

of the input signal to the DSAi

 

 

Series module.

EIA-485

 

 

No computer communication

Incorrect PC set-up

Follow the instructions in the

 

 

DSAPilot Help File for configuring

 

 

PC communications for DSAPilot.

No computer communication

Incorrect connections

Check that EIA-485 cabling to

 

 

both the computer and the module

 

 

is wired correctly for the +/- signal

 

 

wires and cable shield.

No computer communication

Incorrect termination

Ensure that a termination is

 

 

engaged at the EIA-485 port at the

 

 

computer and the Terminate Switch

 

 

is “ON” at the module at the

 

 

farthest end of the EIA-485 cable

 

 

run. All other Terminate Switches

 

 

should be “OFF”.

No computer communication

Module is powered off

Ensure the module is powered on.

No computer communication or

Improper network

Ensure the EIA-485 cabling and

only with some modules

configuration

termination conforms to the notes

 

 

in Section 8.3.

No computer communication

Improper link connections

Ensure the EIA-485 only cabling

 

 

with some modules between

 

 

modules and/or the supplied RJ-45

 

 

Signal Link Cables are connected

 

 

between modules as detailed in this

manual.

35

 

Image 39
Contents Page Safety Precautions Read this First Precauciones DE Seguridad LEA Esto Primero EC Declaration of Conformity Contents Page Shipping Damage ContentsIntroduction UnpackingQuick Start Audio Signal ConnectionChapter Returning Products to EAWDaisy Chaining Audio and Computer Signal Between Modules AC Mains InstallationComputer Control Connection Signal End / Power End Physical InstallationSignal Processing DescriptionSystem Overview 4 DSAi Block Diagrams FeaturesElectronic Engineering Design Applications4a Angled Radiation Pattern Designing DSAi Systems DSAPilotLow Frequency Performance Comparison to Traditional ProductsAnalog Audio and EIA-485 Computer Control Installation2 Audio a & Audio B Recommended Conductor Gauge AWG to 18 AWG / 0.2 mm to 1 mm CobraNet Audio and Computer Control 3 Basic CobraNet DiagramCabling Fault Detect Supervisory Monitoring 3a Single DSAi Fault on 2 PowerCon Plug AC Mains Power Connection4 Fuse Grounding2 Signal End / Power End 3 DSAi Cluster Configurations 4a Wall Mounted 6 Mounting Height Lift the enclosure onto the structure-mounted Wall Brackets Initial Set-Up Acoustical InstallationOperational Functions OperationSignal Monitoring Normal Operation Operational Check ListOperational ‘DOS’ and ‘DONTS’ How to Contact EAW Maintenance and ServiceWarranty Service ItemsAppendices Inspections and MaintenanceDSA250i Only TroubleshootingEIA-485 CobraNet EIA-485 Network NotesSupport For CobraNet Support For EthernetDSAi Connections 3a EIA-485 Example 5c Example One path was to the EIA-485 port. So when B responds 6c Example Right Side Back Mechanical DrawingsRight Side Wall Bracket Full Scale