Foxconn 7870 manual Setting up the Transmitter

Page 16

2.1 Setting up the Transmitter

2.1Setting up the Transmitter

1.Place the 7870T in the 7180M Chassis.

2.Apply AC power to the chassis. The Power Supply and Laser LEDs should be lit.

3.Using an optical power meter, measure the optical power. Insert the meter’s cable into the Transmitter’s optical connector. Power levels should be 0.5 mW minimum (-3 dBm).

Alternatively, use a DVM to measure the voltage at:

7180M Rackmount: Pins J13-P17 through J13-P24 for the slot being measured (See Table 4 7870T Transmitter Pinout on page 20 for details regarding J13 pinouts). [7180M Rackmount]

Standalone: At pin #6 of the 9 pin connector [Standalone]

The signal level should be -4.5 ± -0.3VDC.

4.On the rear panel, connect the coax cable to the RF Input Connector. The RF LED should be lit.

5.On the rear panel, connect the fiber optic cable to the Optical Connector.

Note If either LED is not lit, see Chapter 4 Troubleshooting on page 25.

Caution When monitoring the voltage outputs use only a high resistance DVM.

page 8

Document no. 93-005-35-C5

Image 16
Contents Interfacility Link Installation and User’s Guide CopyrightMailsales@foxcom.com Table of Contents Figures Warranty and Repair Policy General WarrantySpecific Product Warranty Instructions Important InformationReturns Limitations of LiabilitiesPrecautions Personal SafetyEquipment Safety Reporting DefectsImportant Information Options Product Drawings Panel Descriptions Block Diagrams Introduction to the 7870 Interfacility LinkOptions Option LabelProduct Drawings 7870T Transmitter Front and Rear PanelLED Name LED Function Laser Panel DescriptionsLED Name LED Function Opt Block Diagrams 7870Transmitter Block DiagramBlock Diagrams Installation Typical Application of a 7870 Interfacility LinkSetting up the Transmitter Connecting the Fiber Optic Cable Setting Up the Receiver Powering the IFL 1 7180M Chassis 7180M Chassis Rear ViewConnecting the Back Panel Jumpers Jumper Installation Tx and Rx onlyJumper Installation 2040 Switch in slots 2 Fiber Optic Alignment Setup Aligning the Fiber Optic LinkDocument no -005-35-C5 Product Specifications RF SpecificationsOptical Specifications Physical SpecificationsModel Dimensions Unit dimensions7870 Interfacility Link Pinouts 7870R Receiver Pinout 7870 the J11 connector is inoperative 7180M Chassis Pinouts7180M Alarm Connector J12 Pinouts Pin No Function Name Slot No2 7180M Monitor Connector Pinout J13 Pin # Function Name 3 7180M and Redundancy SwitchingTroubleshooting Problem Possible CauseMay still function without LED Appendix 1 Cleaning Fiber Optic Connections Description ManufacturerAppendix 1.1 Cleaning Procedures for FC/APC Connectors Wiping the connector with a Kim wiperAppendix 1.2.1 Swab Method Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead PortsAppendix 1.2.2 Compressed Air Method Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports Appendix 2 Installing a Standalone Unit Document no -005-35-C5 Appendix 2380 Dimensions and Front Panel Label Appendix 3 The 2380 Relay AdapterAppendix 3.1.1 Parts Required for Installing Appendix 3.1 Installing the 2380 Relay AdapterAppendix 3.1.2 Mounting the the 2380 Relay Adapter Mounting the Screws Appendix 3.2 2380 Dimensions and Front Panel Label 2380 DimensionsPin Number Function Appendix Adapter PinoutsSlot Number Pin # Function Name Slot No 2380 Pin NumberAppendix 4 Pinout Charts and Diagrams Standard 7180M and 7180M with 2380 Relay Adapter Pinout 7180M and 2040 RF Switch Pinout Pinout of 7180M Jumper with 2040 RF Switch in slots 2 Pinout of 7180M jumper with 2040 RF switch in slot Pinout of 7180M jumper with 2040 RF switch in slot Page Document no -005-35-C5