A/C on. No cooling (or heating)
Refrigerant is insuffi cient or leaking
Refrigeration system is blocked
Too much refrigerant
The effi ciency of the compressor is low
Condenser can’t discharge smoothly
At the time of heating, the electric heater
can’t run
Outdoor temperature is too high
Check leakage, carry out
Check whether the system is blocked by observing the condensation of the evaporator and the pressure value of the high pressure manometer, and then take measures to deal with the system.
Release the redundant refrigerant in system
Replace the compressor
Get rid of the obstacle
1.the wire is loosened; 2. thermal fuse is broken;
3.temperature limiter is damaged; 4. electric heater is damaged; 5. controller is broken. correct the wore correctly or replace those parts which has malfunction.
You can install the
cooling air is still insuffi cient, you are suggested
to replace the A/C
| Whether the cooling (heating) load is suitable |
|
|
|
|
|
|
| Check the preset cooling (heating) load |
| |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The air tightness in room is not good. People |
|
|
|
|
|
|
| Keep the air tightness well. Try not to use the electic | ||
| come in and go out frequently. There are |
|
| ||
|
|
| appliances with a large quantity of heat | ||
| heating devices in the room when A/C is cooling |
|
| ||
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
Call for fan
motor but fan motor will not come on
Supply voltage is unstable
Wrong wire connection
The fan’s capacitor is broken
The motor winding is of broken circuit or short circuit or the built in temperature limiter device in open circuit due to overheat.
The controller has malfunction
The compressor capacitor is broken; wrong wire
connection
Check the reason and correct it.
Check the circuit and connect the wire correctly
according to the electic circuit diagram
Replace fan’s capacitor with the same
mode and specifi cation
Replace those parts which has malfunction
Replace the controller
Replace capacitor; connect the wire correctly
according to the electric circuit diagram
Compressor isn’t running (controller is with output)
The compressor’s motor is burned out
The compressor is jammed or blocked
Check with a multimeter if the enclosed motor windings of compressor is with short or broken circuit or earthing. If so, it is needed to replace it with the same type and specifi cations.
Knock the compressor housing with a rubber bar or with a hammer padding with a wood, the compressor might be shocked and run. If not, change the compressor.