TROUBLESHOOTING AND REPAIR | ||
|
STATOR REMOVAL AND REPLACEMENT PROCEDURE (continued)
FIGURE F.18 – STATOR REMOVAL
HAMMER TAPPING
POINTS
TOLERANCE RING
BRUSH ASSEMBLY
CAST END BRACKET
BEARING BRACKET END COVER
PROCEDURE
Return to Section
Return to Section TOC
Return to Master
Return to Master TOC
1.Perform the Control Box Removal Procedure.
2.Remove the brushes. See the Brush and Slip Ring Service Procedure.
3.Label and disconnect any wiring connecting the engine/generator assembly to the tubular frame. Remove cable ties and flexible plastic conduit as needed. See wiring diagram.
4.Using the 1/2” wrench, remove the nuts secur- ing the generator and engine to the rubber mounts. Note ground lead and washer place- ment for reassembly. See Figure F.19.
5.Use a hoist or get a helper and lift the engine and generator assembly out of the tubular steel frame. Place the engine and generator assem- bly on a strong, solid work surface.
6.Using a 7/16” wrench, remove the four bolts connecting the cast stator brackets. Note the precise position of all hardware components and washers. Using a plastic hammer, gently and evenly tap outward on the end cast brack- et. See Figure F.18.
The stator frame assembly can now be carefully removed.
IMPORTANT: Handle and store the stator careful- ly to avoid damage to the windings.