TROUBLESHOOTING & REPAIR | |||||
|
|
| |||
|
|
| |||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
| |||
|
|
|
|
| |
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| |
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
| |
|
|
|
|
| |
|
| OUTPUT/FEEDING PROBLEMS |
|
| |
The machine has output, wire | 1. Possible faulty fan motor. | 1. Perform the Fan Motor Test. | |||
feed, gas flow but NO fan. | 2. Possible faulty Control P.C. | 2. Check for continuity between | |||
|
| ||||
|
| Board. | #6 to Fan or #1 to Fan on |
| |
|
|
| Control P.C. Board. Replace. | ||
|
|
| |||
The machine has output, gas | 1. Possible bad drive motor. | 1. Perform the Wire Drive Test. | |||
flow and fan but does not have | 2. Possible bad Control P.C. | 2. If 3 - 30 vdc is not at the drive | |||
wire drive. |
| ||||
| Board. | motor check for OCV at the |
| ||
|
|
| |||
|
|
| board on pins 1 and 10 on J3. | ||
|
|
| If OCV is present possible |
| |
|
|
| faulty Control P.C Board. |
| |
|
|
| Replace. If OCV is not |
| |
|
|
| present check continuity of |
| |
|
|
| wires CAP- and CAP+. |
| |
|
|
| |||
No wire feed when gun trigger is | 1. If the wire drive motor is | 1. Perform the Wire Drive Test. | |||
pulled. Fan runs, gas flows and | running, make sure that the | 2. If wire drive test is OK, then |
| ||
machine has correct open circuit | correct drive roll and wire |
| |||
check for OCV at CAP- and |
| ||||
voltage. ( 33 vdc maximum) - | guide is installed in the |
| |||
CAP+ on the control board. If | |||||
weld output. |
| machine. | |||
| correct voltage is present, |
| |||
|
|
|
| ||
|
| 2. Check for clogged cable liner | possible faulty Control P.C. |
| |
|
| or contact tip. | Board. Replace. |
| |
|
| 3. Check for proper size cable | 3. If open circuit voltage is not |
| |
|
| liner and contact tip. | present at CAP- and CAP+ on | ||
|
|
| control board check continuity | ||
|
|
| of leads. |
| |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call