TROUBLESHOOTING & REPAIR | ||||
|
|
| ||
|
|
| ||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
| ||
|
|
|
|
|
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
|
| WELDING PROBLEMS |
|
|
The arc is unstable - poor |
| 1. Check for correct input voltage | 1. Check for 17 to 33 VDC |
|
starting. |
| to the machine. | (dependent on Arc Voltage |
|
|
| 2. Check for proper electrode | Control Setting) at the |
|
|
| machine’s output terminals. If | ||
|
| polarity for process. | ||
|
| present check gun and work | ||
|
|
| ||
|
| 3. Check gun tip for wear or | cable. |
|
|
|
|
| |
|
| 2. If OCV is low, check output |
| |
|
|
|
| |
|
| 4. Check for proper gas and flow | capacitor and output diodes. | |
|
|
|
| |
|
| rate for process. | 3. Check for loose connections | |
|
|
| ||
|
| 5. Check work cable for loose or | at the output terminals, the |
|
|
| choke and all heavy current |
| |
|
| faulty connections. |
| |
|
| carrying leads. See Wiring |
| |
|
|
|
| |
|
| 6. Check gun for damage or | Diagram. |
|
|
| breaks | 4. The Control P.C. Board may |
|
|
|
|
| |
|
|
| be faulty. Replace. |
|
|
|
|
|
|
|
| GAS FLOW PROBLEMS |
|
|
Low or no gas flow when gun | 1. Check gas supply, flow | 1. Check the gas solenoid by |
| |
trigger is pulled. Wire feed, weld | regulator and gas hoses. | disconnecting it from the |
| |
output and fan operate normally. | 2. Check gun connection to | control board and applying a | ||
|
| 12 vdc external supply to the | ||
|
| machine for obstruction or | ||
|
| gas solenoid. If solenoid does | ||
|
| leaky seals. | ||
|
| not activate it may be faulty. | ||
|
|
| Replace. |
|
|
|
| 2. The control P.C. board may |
|
|
|
| be faulty. Replace. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call