Lincoln Electric SP-100T manual Select Suitable Location, Output Connections, Stacking, Tilting

Page 10

A-3

INSTALLATION

A-3

 

 

 

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front of the unit. A location that minimizes the amount of smoke and dirt drawn into the rear louvers reduces the chance of dirt accumulation that can block air passages and cause overheating.

STACKING

SP-100T’s cannot be stacked.

TILTING

Each machine must be placed on a secure, level sur- face, either directly or on either recommended cart. The machine may topple over if this procedure is not followed.

OUTPUT CONNECTIONS

Refer to Figure A.2.

1.Work Cable Access Hole.

2.Gun Cable and Control Lead Access Hole.

3.Connector Block.

4.Gun Trigger Lead Connectors.

5.Positive (+) and negative (–) output terminals.

6.Wire Feed Gearbox.

7.Cable Hanger.

8.Thumbscrew.

Work Clamp Installation

Attach the work clamp per the following:

1.Unplug the machine or turn the power switch to the “OFF” position.

2.Insert the work cable terminal lug with the larger hole through the strain relief hole in the work clamp as shown in Figure A-3.

3.Fasten securely with the bolt and nut provided.

FIGURE A.3

Strain Relief Hole

Work Cable

Nut & Bolt

Work Clamp

DO NOT SWITCH

WHEN WELDING

SP-100T

1 2

4

5

+

8

-

3 67

FIGURE A.2

SP-100T

Image 10
Contents SP-100T Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationMaster Table of Contents for ALL Sections Installation Technical Specifications SP-100TIdentify and Locate Components Safety PrecautionsElectric Shock can kill Output Connections Work Clamp InstallationSelect Suitable Location StackingConnecting Gun Cable to the SP-100T GUN InstallationWork Cable Installation GAS ConnectionFigure A.5 Code Requirements for Input Connections Input ConnectionsRequirements For Rated Output Requirements For CSA Rated OutputGeneral Description Design FeaturesOperation Recommended ProcessesWelding Capability Controls and SettingsLimitations Welding Operations Wire LoadingSequence of Operation Friction Brake Adjustment Wire ThreadingProcess Guidelines Cleaning Tip And NozzleMaking a Weld Welding with Gmaw MIG Changing Machine Over to Feed Other Wire SizesOverload Protection Application Chart K586-1 Deluxe Adjustable Gas Regulator Hose Kit AccessoriesOptional Accessories K549-1 .035 0.9 mm Innershield Welding KitReplacement Parts Innershield Fcaw ConversionMaintenance Safety Precautions MaintenanceRoutine Maintenance For Magnum 100L GUN GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System Contact Tip Cable Liner Drive RollChanging the Contact TIP Component Replacement ProceduresChanging Drive Roll Changing Liner Liner trim lengthGUN Handle Parts Figure D.3Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Troubleshooting GuideRecommended Course of Action Feeding Problems Welding Problems SP-100T Wiring Diagram DiagramsPrecaucion Warnung