Lincoln Electric SP-100T manual Safety Precautions, Identify and Locate Components

Page 9

A-2

INSTALLATION

A-2

 

 

 

Read entire installation section before starting installation.

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should perform this installation.

Only personnel that have read and under-

stood the SP-100T Operating Manual should install and operate this equipment.

Machine must be plugged into a receptacle which is grounded per any national, local or other applicable electrical codes.

The SP-100T power switch is to be in the OFF (“O”) position when installing work cable and gun and when connecting power cord to input power.

IDENTIFY AND LOCATE

COMPONENTS

If you have not already done so, unpack the SP-100T from its carton and remove all packing material around the SP-100T. Remove the following loose items from the carton (see Figure A.1):

1.SP-100T

2.Gun and cable assembly(1)

3.Literature and miscellaneous including:

a)This operating manual

b)6 extra .023"-.025” (0.6 mm) contact tips

c)Hex key wrench for removal of drive roll.

4.10 ft (3.0 m) work cable.

5.Work clamp.

6.2Lb. spool of .025” (0.6 mm)Super Arc L-56 MIG wire.

7.Handshield with filter plate and lens.

8.Instructional video.

9.Adjustable mixed-Gas Regulator & Hose.

For available options and accessories refer to the Accessories Section of this manual.

1)As shipped from the factory, the SP-100T gun liner is ready to feed .023” (0.6 mm) -.035 (0.9 mm) wire. The contact tip is sized for .023”-.025” (0.6 mm) wire .

SP-100T

FIGURE A.1

2

1

4

6

3

5

8

 

7

9

Image 9
Contents SP-100T California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyMaster Table of Contents for ALL Sections Technical Specifications SP-100T InstallationSafety Precautions Identify and Locate ComponentsElectric Shock can kill Select Suitable Location Work Clamp InstallationOutput Connections StackingWork Cable Installation GUN InstallationConnecting Gun Cable to the SP-100T GAS ConnectionFigure A.5 Requirements For Rated Output Input ConnectionsCode Requirements for Input Connections Requirements For CSA Rated OutputOperation Design FeaturesGeneral Description Recommended ProcessesControls and Settings Welding CapabilityLimitations Wire Loading Welding OperationsSequence of Operation Wire Threading Friction Brake AdjustmentCleaning Tip And Nozzle Process GuidelinesMaking a Weld Changing Machine Over to Feed Other Wire Sizes Welding with Gmaw MIGOverload Protection Application Chart Optional Accessories AccessoriesK586-1 Deluxe Adjustable Gas Regulator Hose Kit K549-1 .035 0.9 mm Innershield Welding KitInnershield Fcaw Conversion Replacement PartsMaintenance Maintenance Safety PrecautionsRoutine Maintenance Configuration of Components in Wire Feeding System GUN and Cable MaintenanceFor Magnum 100L GUN Contact Tip Cable Liner Drive RollComponent Replacement Procedures Changing the Contact TIPChanging Drive Roll Liner trim length Changing LinerFigure D.3 GUN Handle PartsHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Guide Problems Possible Areas Symptoms MisadjustmentsRecommended Course of Action Feeding Problems Welding Problems Diagrams SP-100T Wiring DiagramPrecaucion Warnung