Lincoln Electric SP-100T manual Innershield Fcaw Conversion, Replacement Parts

Page 22

C-2

ACCESSORIES

C-2

 

 

 

INNERSHIELD (FCAW)

CONVERSION

Several changes are needed to convert the unit for operation with the Innershield (FCAW) process. The K549-1 Innershield Kit include’s all the necessary accessories for this conversion and is provided for this purpose. The following conversions should be made using the contents of this kit:

1.Change the output polarity to DC(–). See “Work Cable Installation” in Installation section for details.

2.Install proper drive roll for the wire size selected. See “Changing Drive Roll” in Maintenance section for details.

3.Install the proper gun liner and tip for the wire size selected. See “Component Replacement” in Maintenance section for details.

4.Remove gas nozzle (if installed) and install gasless nozzle. To remove, simply unscrew.

5.Load wire into machine and thread into gun and cable per “Welding Wire Loading” section.

REPLACEMENT PARTS

Complete Gun and Cable Assembly

(K530-5)

Contact Tip .025” (0.6 mm)

KP2039-1

Contact Tip .030” (0.8 mm)

KP2039-2

Contact Tip .035” (0.9 mm)

KP2039-3

Contact Tip-Tapered .025” (0.6 mm) KP2052-1

Contact Tip-Tapered .030” (0.8 mm) KP2052-2

Contact Tip-Tapered .035” (0.9 mm) KP2052-3

Liner .035/.045” (0.9/1.2 mm)

KP1937-1

Gas Diffuser

KP2040-1

Gas Nozzle

KP1938-1

Gas Nozzle-Tip Recessed 3/8” (9.5 mm) Opening I.D.

KP1942-1

Gas Nozzle-Tip Recessed 1/2” (12.7 mm) Opening I.D.

KP1942-2

Gas Nozzle-Tip Recessed 5/8” (15.9 mm) Opening I.D.

KP1942-3

Spot Welding Nozzle

KP1956-1

Gasless Nozzle (Innershield Only)

KP1939-1

SP-100T

Image 22
Contents SP-100T Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationMaster Table of Contents for ALL Sections Installation Technical Specifications SP-100TIdentify and Locate Components Safety PrecautionsElectric Shock can kill Output Connections Work Clamp InstallationSelect Suitable Location StackingConnecting Gun Cable to the SP-100T GUN InstallationWork Cable Installation GAS ConnectionFigure A.5 Code Requirements for Input Connections Input ConnectionsRequirements For Rated Output Requirements For CSA Rated OutputGeneral Description Design FeaturesOperation Recommended ProcessesWelding Capability Controls and SettingsLimitations Welding Operations Wire LoadingSequence of Operation Friction Brake Adjustment Wire ThreadingProcess Guidelines Cleaning Tip And NozzleMaking a Weld Welding with Gmaw MIG Changing Machine Over to Feed Other Wire SizesOverload Protection Application Chart K586-1 Deluxe Adjustable Gas Regulator Hose Kit AccessoriesOptional Accessories K549-1 .035 0.9 mm Innershield Welding KitReplacement Parts Innershield Fcaw ConversionMaintenance Safety Precautions MaintenanceRoutine Maintenance For Magnum 100L GUN GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System Contact Tip Cable Liner Drive RollChanging the Contact TIP Component Replacement ProceduresChanging Drive Roll Changing Liner Liner trim lengthGUN Handle Parts Figure D.3Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Troubleshooting GuideRecommended Course of Action Feeding Problems Welding Problems SP-100T Wiring Diagram DiagramsPrecaucion Warnung