Lincoln Electric FX450 CAbLE Connections, PIN Remote Control Connector, Function Pin Wiring

Page 12

A-5

INSTALLATION

A-5

 

 

 

E F

A D

C B

CAbLE CONNECTIONS

See FIGuRE A.2 for locating 6-pinand 14-pincon- nectors on the front of the FX450.

6-PIN REMOTE CONTROL CONNECTOR

Function

Pin

 

Wiring

 

 

 

 

6-pin remote

A

77

Remote potentiometer, 5K

control con-

B

76

Remote potentiometer, wiper

nector for

C

75

Remote potentiometer, common

remote or

D

Trigger, common

hand/foot

E

Trigger, input

amptrol.

F

Ground

 

 

 

 

F

G

H

I

 

 

N

 

 

 

J

 

M

 

 

K

 

E

 

A

L

 

 

D

C B

 

14-PIN CONNECTOR FOR WIRE FEEDER

Function

Pin

Wiring

 

 

 

14 pin con-

A

 

nector for

B

Ground

wire feeder

C

Trigger, Common

connectivity.

D

Trigger input

 

E

77 Remote potentiometer, 5K

 

F

76 Remote potentiometer, wiper

 

G

75 Remote potentiometer, common

 

H

Voltage Sense (21)

 

I

Motor (42 VAC)

 

J

 

 

K

Motor (42 VAC)

 

L

 

 

M

 

 

N

 

 

 

 

FIGuRE A.2

14-PIN CONNECTOR

6-PIN REMOTEFOR WIRE FEEDER CONTROL CONNECTOR

FX450 (RED-D-ARC)

Image 12
Contents RED-D-ARC Safety California Proposition 65 WarningsElectric Shock can kill ARC Rays can burnWelding and Cutting Sparks can Cause fire or explosion Cylinder may explode if damagedIii PRÉCAuTIONS DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately CuSTOMER Assistance PolicyTAbLE of Contents Installation TEChNICAL Specifications FX450Voltage FX450 RED-D-ARCProcess ModelLifting StackingEnvironmental Limitations INPuT FuSE and SuPPLY Wire Considerations INPuT ConnectionINPuT Voltage Selection PIN Remote Control Connector Function Pin WiringPIN Connector for Wire Feeder CAbLE ConnectionsRecommended Electrode and Work CAbLE SIzES for ARC Welding Control CAbLE ConnectionsGeneral Guidelines TAbLE A.1 OuTPuT CAbLE GuIDELINESSafety PRECAuTIONS Wire FeederOperation OFFPRODuCT Description VoltageProtective EQuIPMENT EQuIPMENT LimitationsRecommended Processes Process LimitationsCase Front Control Descriptions FIGuRE b.1Common Welding PROCEDuRES Input Power Cord Access holeCase bACK Control Weld Controls and DisplaysWeld Terminals On/Remote Toggle Switch Control Local/Remote Toggle SwitchBASIC Modes of Operation Thermal LightGtaw CV-GASWeld Terminals On/Remote CV-INNERShIELD Accessories Options / AccessoriesGeneral Options TIG OptionsMaintenance ROuTINE MaintenancePERIODIC MAINTENANCE Thermal ProtectionTROubLEShOOTING HOW to uSE TROubLEShOOTING GuIDEPRObLEMS SymptomsPOSSIbLE CAuSE RecommendedUSING ThE STATuS LED to TROubLEShOOT System PRObLEMS Error Codes for the FX450Diagrams FX450 RED-D-ARCDimension Print Precaucion Warnung