TROubLEShOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PRObLEMS
(SYMPTOMS)
POSSIbLE
CAuSE
RECOMMENDED
COuRSE OF ACTION
| Major physical or electrical damage | 1. Contact your local authorized |
| is evident when the sheet metal | Field Service facility for technical |
| covers are removed. | assistance. |
| Machine won’t weld, can’t get any | 1. If the displays show an Err ### |
| output. | see the fault section for corrective |
|
| action. |
|
| 2 If the thermal symbol is lit refer to |
|
| the thermal section. |
|
| 3 If the output terminals are in |
|
| remote control switch to "ON" and |
|
| check for output voltage. If output |
|
| voltage is now present check for |
|
| correct remote control connection |
|
| and operation. |
|
|
|
| Thermal symbol is lit. | 1. Check for proper fan operation. |
|
| • Check for material blocking |
|
| intake or exhaust louvers. |
|
| • Blow air in the rear louvers to |
|
| clear dirt from the fan. |
|
| Note: The Fan As Needed circuitry |
|
| automatically shuts off the fan |
|
| 5 minutes after welding has |
|
| stopped. |
|
| 2. Welding output ratings may have |
|
| been exceeded. Allow the |
|
| machine to cool down and reset. |
|
|
|
| Wire feeder won’t work. Apparently | 1. Check circuit breakers by the wire |
| no power to wire feeder | feeder receptacles on the rear of |
|
| the machine. Reset |
|
| 2. Check the control cable between |
|
| the power source and the wire |
|
| feeder for continuity. |
|
|
|
|
|
|
1.If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Authorized Field Service Facility.
CAuTION