Lincoln Electric FX450 EQuIPMENT Limitations, Recommended Processes, Process Limitations

Page 16

b-3

OPERATION

b-3

 

 

 

RECOMMENDED PROCESSES AND

EQuIPMENT

RECOMMENDED PROCESSES

The FX450 is designed for CC-SMAW, CC-GTAW (lift tig), CV-GMAW, CV-FCAW-SS and CV-FCAW-GS welding processes. CAG (arc gouging) is also supported.

PROCESS LIMITATIONS

The FX450 is suitable only for the processes listed.

EQuIPMENT LIMITATIONS

Operating Temperature Range is -10° C to + 55° C.

Output De-rated at Temperatures above 40°C.

COMMON EQuIPMENT PACKAGES

basic Package

K3073-1

FX450

K2327-5

LF-72 Bench Model

K2149-1

Work Lead Package

K1842-10

10 Ft. Weld Power Cable

3100211

Harris Regulator and gas hose

 

 

 

Common Optional Kits

 

 

K857

Remote Output Control (25 feet)

K857-1

Remote Output Control (100 feet)

K870

Foot Amptrol

K963-3

Hand Amptrol

 

 

Compatible Wire Feeders

All Models

LF-72

LF-74

LN-10

DH-10

LN-25 Pro

Note: The FX450 is not compatible with 115V Wire Feeders.

FX450 (RED-D-ARC)

Image 16
Contents RED-D-ARC Safety California Proposition 65 WarningsElectric Shock can kill ARC Rays can burnCylinder may explode if damaged Welding and Cutting Sparks can Cause fire or explosionIii PRÉCAuTIONS DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately CuSTOMER Assistance PolicyTAbLE of Contents Installation TEChNICAL Specifications FX450Voltage FX450 RED-D-ARCProcess ModelStacking LiftingEnvironmental Limitations INPuT Connection INPuT FuSE and SuPPLY Wire ConsiderationsINPuT Voltage Selection PIN Remote Control Connector Function Pin WiringPIN Connector for Wire Feeder CAbLE ConnectionsRecommended Electrode and Work CAbLE SIzES for ARC Welding Control CAbLE ConnectionsGeneral Guidelines TAbLE A.1 OuTPuT CAbLE GuIDELINESSafety PRECAuTIONS Wire FeederOperation OFFVoltage PRODuCT DescriptionProtective EQuIPMENT EQuIPMENT LimitationsRecommended Processes Process LimitationsCase Front Control Descriptions FIGuRE b.1Common Welding PROCEDuRES Input Power Cord Access holeCase bACK Control Weld Controls and DisplaysWeld Terminals On/Remote Toggle Switch Control Local/Remote Toggle SwitchBASIC Modes of Operation Thermal LightCV-GAS GtawWeld Terminals On/Remote CV-INNERShIELD Accessories Options / AccessoriesGeneral Options TIG OptionsMaintenance ROuTINE MaintenancePERIODIC MAINTENANCE Thermal ProtectionTROubLEShOOTING HOW to uSE TROubLEShOOTING GuIDEPRObLEMS SymptomsPOSSIbLE CAuSE RecommendedUSING ThE STATuS LED to TROubLEShOOT System PRObLEMS Error Codes for the FX450Diagrams FX450 RED-D-ARCDimension Print Precaucion Warnung