Lincoln Electric Installation, TEChNICAL Specifications FX450, Voltage, FX450 RED-D-ARC

Page 8

 

A-1

 

 

 

 

 

 

 

INSTALLATION

 

 

 

 

 

 

 

A-1

 

TEChNICAL SPECIFICATIONS - FX450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOuRCE-INPuT VOLTAGE AND CuRRENT

 

 

 

 

 

Model

 

 

 

Duty Cycle

Input Voltage ± 10%

Input Amperes

 

Idle Power

 

Power Factor @

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60% rating

 

 

37 / 27 / 22

 

 

72 Watts

 

 

 

 

K3073-1

 

 

 

 

 

 

380 / 460 / 575 / 3 / 50 / 60

 

 

 

 

 

 

Max.

 

 

95%

 

 

 

 

 

100% rating

 

 

 

 

 

 

 

 

 

 

 

 

 

29 / 21 / 17

 

 

 

 

 

 

 

 

 

 

 

 

 

(fan on)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OuTPuT

 

 

 

 

 

 

 

 

 

 

Process

 

 

 

Duty Cycle

Volts at Rated Amperes

 

 

 

 

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

 

 

36.5V

 

 

 

 

 

 

 

450

 

 

 

 

GMAW (CV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

34V

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

 

 

28V

 

 

 

 

 

 

 

450

 

 

 

 

GTAW (CC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

26V

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

 

 

38V

 

 

 

 

 

 

 

450

 

 

 

 

SMAW (CC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

36V

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

 

 

36.5V

 

 

 

 

 

 

 

450

 

 

 

 

FCAW-GS (CV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

34V

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60%

 

 

36.5V

 

 

 

 

 

 

 

450

 

 

 

 

FCAW-SS (CV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

34V

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPuT WIRE AND FuSE SIzES (1)

 

 

 

 

 

VOLTAGE

Maximum

 

Cord Size(3)

Type 75°C Copper

COPPER GROuNDING

Fuse (Super Lag) or

 

 

50/60hz

 

Input

 

AWG SIzES

Wire in Conduit

 

CONDuCTOR

 

Breaker Size (2)

 

 

 

Amperes

 

 

(mm)

AWG (mm2)

 

 

AWG (mm2)

 

 

 

 

 

380/3/50

 

42 A

 

 

8(10)

8 (10)

 

 

 

 

10 (6)

 

 

50

 

 

460/3/60

 

30 A

 

 

8(10)

10 (6)

 

 

 

 

10 (6)

 

 

45

 

 

575/3/60

 

25 A

 

 

10(6)

12 (4)

 

 

 

 

12 (4)

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.

(2)Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the magnitude of current increases.

(3)Type SD cord or similar in 30°C ambient.

FX450 (RED-D-ARC)

Image 8
Contents RED-D-ARC Safety California Proposition 65 WarningsElectric Shock can kill ARC Rays can burnIii Welding and Cutting Sparks can Cause fire or explosionCylinder may explode if damaged PRÉCAuTIONS DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately CuSTOMER Assistance PolicyTAbLE of Contents Installation TEChNICAL Specifications FX450Voltage FX450 RED-D-ARCProcess ModelEnvironmental Limitations LiftingStacking INPuT Voltage Selection INPuT FuSE and SuPPLY Wire ConsiderationsINPuT Connection PIN Remote Control Connector Function Pin WiringPIN Connector for Wire Feeder CAbLE ConnectionsRecommended Electrode and Work CAbLE SIzES for ARC Welding Control CAbLE ConnectionsGeneral Guidelines TAbLE A.1 OuTPuT CAbLE GuIDELINESSafety PRECAuTIONS Wire FeederOperation OFFProtective PRODuCT DescriptionVoltage EQuIPMENT EQuIPMENT LimitationsRecommended Processes Process LimitationsCase Front Control Descriptions FIGuRE b.1Common Welding PROCEDuRES Input Power Cord Access holeCase bACK Control Weld Controls and DisplaysWeld Terminals On/Remote Toggle Switch Control Local/Remote Toggle SwitchBASIC Modes of Operation Thermal LightWeld Terminals On/Remote GtawCV-GAS CV-INNERShIELD Accessories Options / AccessoriesGeneral Options TIG OptionsMaintenance ROuTINE MaintenancePERIODIC MAINTENANCE Thermal ProtectionTROubLEShOOTING HOW to uSE TROubLEShOOTING GuIDEPRObLEMS SymptomsPOSSIbLE CAuSE RecommendedUSING ThE STATuS LED to TROubLEShOOT System PRObLEMS Error Codes for the FX450Diagrams FX450 RED-D-ARCDimension Print Precaucion Warnung