Lincoln Electric IM849 manual END Options, Setup Mode Options, Set Timers, Yes

Page 23

B-8

OPERATION

B-8

 

 

 

END OPTIONS

Pressing the Right Mode Select Panel Pushbutton after scrolling through the Start Options will illuminate the END OPTIONS LED. Repeated pressing of the Right Mode Select Panel Pushbutton will toggle through the parameters. Turning the Mode Select Panel Knob while on a parameter will change its value. When the Crater Time is set to a value other than OFF, the END OPTIONS LED will blink synchro- nous with the WFS or Amps LED (depending on CC or CV Weld Modes) and with the Volts LED located on the Dual Display Panel prompting the user to enter these parameters. The parameters that can be set by the user in the END OPTIONS will be as follows:

CRATER WFS/AMPS (Dual Display)

CRATER VOLTS (Dual Display)

CRATER TIME (MSP4)

BURNBACK TIME (MSP4)

1.3 Seconds

Crater Time

SETUP MODE OPTIONS

The Setup Mode can be entered at any time by press- ing both Mode Select Panel Pushbuttons simultane- ously. The SETUP LED will illuminate. Pressing both Mode Select Panel Pushbuttons simultaneously while the P number is blinking will exit the Setup Mode. The Setup Mode will be exited automatically after 1 minute of inactivity.

There are two different levels of user preferences in the Setup Mode – non-secure and secure. Accessing secured parameters requires initialization using a Palm or PC utility.

Welding parameters that will be factory set to default values or adjusted by a relatively small percentage of users will be made available in the SETUP MODE. These parameters will include the following:

STRIKE FAULT TIME (MSP4-seconds)

START ARC FORCE (Dual Display-Amps)

DOWNSLOPE TIME (MSP4-seconds)

UPSLOPE TIME (MSP4-seconds)

CRATER ARC FORCE (Dual Display-Amps)

WELD ARC FORCE (Dual Display-Amps)

P.11

Set

 

 

Timers

 

SETU P

 

 

 

 

 

 

Yes

 

 

 

 

 

RESTRIKE TIME (MSP4-seconds)

Turning the Mode Select Panel Knob will toggle through all user preferences and factory set welding parameters. The lower alphanumeric display will read

"Yes" prompting the user to press the right Pushbutton to enter into the chosen parameter set, if available.

Once the parameter set has been selected, turning the Mode Select Panel Knob will toggle through the parameters available in the selected set while show- ing the current setting for each parameter in the 7- segment display. The parameters will blink in the Mode Select Panel lower alphanumeric display prompting the user to press the right Mode Select Panel Pushbutton to select the parameter. Once the parameter has been selected, the lower Mode Select Panel alphanumeric display will no longer blink the parameter and the current setting of the parameter will blink in the Mode Select Panel 7-segment display prompting the user to change the setting. Pressing the left Mode Select Panel Pushbutton will exit the para- meter setting section, returning to the previous sec- tion. Continuing to press the left Mode Select Panel Pushbutton will return to the Setup Mode user prefer- ences and welding parameters list.

0.3

Seconds

SETUP

 

 

Downslope Time

 

 

 

 

POWER FEED™ 10A CONTROLLER

Image 23
Contents Power Feed 10A Controller California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents General Information Technical Specifications Power Feed 10A ControllerPower Feed 10A Controller Safety Precaution InstallationConverting Switch Panel to a remote pendant Interfacing to the Power Feed 10A ControllerAuxiliary Input Power Connection Instructions Interfacing to the Switch Panel Controls Figure A.2 Controlling NON-LINCOLN Auxiliary EquipmentStop Input Shutdown InputsPower Feed 10A Controller Control BOX Connection Diagram SystemWelding with Multiple Arcs Remote Sense Lead SpecificationsCommon Welding Abbreviations Design FeaturesOperation Definitions of Welding ModesEquipment Limitations Product DescriptionRecommended Processes Process LimitationsControl BOX With Door Control BOX Without Door Power Feed 10A ControllerLocating Front Panel Controls and INPUT, Ouput Connections LED condition Definition Case Front Controls Case Front Control DescriptionsTravel Mode POWER-UP SequenceWire Feeder Setup Inch Wire Feed Speed SettingDescription Changing Weld Modes Weld Mode DescriptionMode Select Panel 4 MSP4 Table B.1Start Options AC ControlEND Options Setup Mode OptionsSet Timers SetupWeld Sequence Parameter List Parameter Units Range Default Value Where is IT SET?General Setup Mode Options Panel Infrared IR ControlLOCKOUT/SECURITY Memory Saving Procedure Memory VS. User MemoryMulti Procedure Welding Memory RecallingAttribute Limit SettingHigh Limit General Options Accessories AccessoriesPeriodic Maintenance MaintenanceSafety Precautions Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingYour local Lincoln Authorized Field Service Facility LINC-NET System Error CodesYour local Lincoln Authorized Field Service FacilityContact your local Lincoln Output Problems Troubleshooting Power Feed 10A Controller M20414 DimensionprintPrecaucion Warnung