Lincoln Electric IM849 manual Your local Lincoln Authorized, Field Service Facility

Page 33

E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

ARCLINK SYSTEM ERROR CODES

Err 33

Capacitor bank "B" under

1.

The power source input power

 

 

voltage.

 

may be wired incorrectly. Verify

 

 

 

 

 

the power

source reconnect

 

 

 

 

 

panel wiring matches the input

 

 

 

 

 

power.

 

 

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

Err 34

Capacitor bank "A" overvolt-

1.

The power source input power

 

 

 

age.

 

may be wired incorrectly. Verify

 

 

 

 

 

the power

source reconnect

 

 

 

 

 

panel wiring matches the input

 

 

 

 

 

power.

 

 

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

Err 35

Capacitor bank "B" overvolt-

1.

The power source input power

 

 

 

age.

 

may be wired incorrectly. Verify

 

 

 

 

 

the power

source reconnect

If all recommended possible areas of

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

misadjustment have been checked

 

 

 

 

 

 

and the problem persists, Contact

 

 

 

2.

See the power source Instruction

your local Lincoln Authorized

 

 

 

 

Manual.

 

Field Service Facility.

 

 

 

 

 

Err 36

Thermal

1.

Power source overheating. Verify

 

 

 

 

 

 

duty cycle is correct. Ensure ade-

 

 

 

 

 

quate airflow around power

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

Err 41

Long term secondary over-

1.

The power source has exceeded

 

 

 

current.

 

the output current limits. Adjust

 

 

 

 

 

the welding procedure to reduce

 

 

 

 

 

the current draw. The welding

 

 

 

 

 

procedure

may exceed the

 

 

 

 

 

capacity of the power source.

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

Err 43

Capacitors are out of bal-

1.

Verify the power source recon-

 

 

 

ance

 

nect panel wiring matches the

 

 

 

 

 

input power.

 

 

 

 

 

 

2.

See the power source Instruction

 

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

Image 33
Contents Power Feed 10A Controller California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Power Feed 10A Controller Power Feed 10A ControllerGeneral Information Safety Precaution InstallationInterfacing to the Power Feed 10A Controller Auxiliary Input Power Connection InstructionsConverting Switch Panel to a remote pendant Interfacing to the Switch Panel Controls Figure A.2 Controlling NON-LINCOLN Auxiliary EquipmentStop Input Shutdown InputsPower Feed 10A Controller Control BOX Connection Diagram SystemWelding with Multiple Arcs Remote Sense Lead SpecificationsOperation Design FeaturesDefinitions of Welding Modes Common Welding AbbreviationsRecommended Processes Product DescriptionProcess Limitations Equipment LimitationsControl BOX Without Door Power Feed 10A Controller Locating Front Panel Controls and INPUT, Ouput ConnectionsControl BOX With Door LED condition Definition Case Front Controls Case Front Control DescriptionsWire Feeder Setup POWER-UP SequenceInch Wire Feed Speed Setting Travel ModeMode Select Panel 4 MSP4 Changing Weld Modes Weld Mode DescriptionTable B.1 DescriptionStart Options AC ControlSet Timers Setup Mode OptionsSetup END OptionsWeld Sequence Parameter List Parameter Units Range Default Value Where is IT SET?General Setup Mode Options Infrared IR Control LOCKOUT/SECURITYPanel Multi Procedure Welding Procedure Memory VS. User MemoryMemory Recalling Memory SavingLimit Setting High LimitAttribute General Options Accessories AccessoriesSafety Precautions MaintenanceRoutine Maintenance Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingYour local Lincoln Authorized Field Service Facility LINC-NET System Error CodesYour local Lincoln Authorized Field Service FacilityContact your local Lincoln Output Problems Troubleshooting Power Feed 10A Controller M20414 DimensionprintPrecaucion Warnung