B-13

 

 

 

LIMIT SETTING

Each user memory can be optionally configured to limit the user’s range of control over some user interface set- tings. By default, user limits are not enabled. To set lim- its for a selected memory, first select a weld mode and perform a memory save. Next, press and hold the mem- ory button for five seconds. Release the memory button when the memory LED begins to blink rapidly and the Mode Select Panel displays indicate "Set Limits".

If the passcode has been set to a value other than zero, the user will be prompted to enter it. If the passcode is zero, the Mode Select Panel will immediately display the Limit Setup menu and the SETUP LED will illuminate:

 

200

HI=

220

IR PORT

LO=

180

 

 

 

SETUP

 

WELD

WFS

 

WELD MODE

 

 

START OPTIONS

ARC CONTROL

 

 

END OPTIONS

 

SET

 

 

The above example shows a wire mode, constant current weld modes would show "Weld Amps" rather than "Weld WFS".

There are four items displayed on each Limit Setup screen. The long alphanumeric display shows the selected attribute (e.g. Weld WFS,Volts, etc.). The short alphanumeric displays show the selected attribute’s high and low user limits. The 7-segment displays show the value that is copied to procedure memory when a memo- ry recall is performed.

One of these four items will blink to indicate which item will change when the Mode Select Panel Knob is rotated. Initially, the selected item will be the attribute. To select the high limit, press either Mode Select Panel button and the high limit value will begin to blink. Pressing either Mode Select Panel button again will cause the memory value to blink, pressing a third time will cause the low limit to blink.

Weld modes cannot be selected from the Limits Setup menu; the mode must be selected and saved to memory prior to entering the Limits Setup menu.

The memory value, high and low limit values are bound by the limits of the machine. For example, weld mode 49 may allow the wire feed speed to be adjusted between 10 and 200 in/min. These are referred to as "machine limits". Machine limits can vary between power sources and are also weld mode dependent.

The memory value must always be less than or equal to the high limit and greater than or equal to the low limit. The high limit must always be greater than or equal to the low limit and the low limit must always be less than or equal to the high limit. The rules are enforced automati- cally. If the low limit is increased above the memory value, the memory value will automatically increase.

To lock an attribute to a specific value, set the high and low limits to the desired value. The user will not be able to change it.

After setting limits, press the memory button that is flash- ing. The Mode Select Panel displays will prompt the user to save or discard the limit changes just made.

By pressing the Mode Select Panel button labeled YES, changes to limits are saved and user limits are automati- cally enabled. By pressing NO, any changes made to limits are dicarded and the limit enable/disable state is not changed.

Memory Value

 

 

High Limit

 

 

Low Limit

 

 

 

 

200

HI=

220

IR PORT

LO=

180

 

 

 

SETUP

 

WELD

WFS

 

WELD MODE

 

 

START OPTIONS

ARC CONTROL

 

 

END OPTIONS

SET

Attribute

 

ENABLE

IR PORT

LIMITS?

 

SETUP

Yes

No

WELD MODE

START OPTIONS

AC CONTROL

END OPTIONS

 

SET

To enable or disable limits that have been established for any memory, press and hold the respective memory but- ton in for more than 10 seconds until the Mode Select Panel displays "Enable Limits?" Pressing "Yes" will use the established limits, while pressing "No" will ignore the established limits. The limits that have been set for any memory location will not be erased if they are disabled.

POWER FEED™ 10A CONTROLLER

Image 28
Contents Power Feed 10A Controller Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Power Feed 10A Controller Technical Specifications Power Feed 10A ControllerGeneral Information Installation Safety PrecautionAuxiliary Input Power Connection Instructions Interfacing to the Power Feed 10A ControllerConverting Switch Panel to a remote pendant Interfacing to the Switch Panel Controls Controlling NON-LINCOLN Auxiliary Equipment Figure A.2Shutdown Inputs Stop InputConnection Diagram System Power Feed 10A Controller Control BOXRemote Sense Lead Specifications Welding with Multiple ArcsDesign Features OperationDefinitions of Welding Modes Common Welding AbbreviationsProduct Description Recommended ProcessesProcess Limitations Equipment LimitationsLocating Front Panel Controls and INPUT, Ouput Connections Control BOX Without Door Power Feed 10A ControllerControl BOX With Door Case Front Controls Case Front Control Descriptions LED condition DefinitionPOWER-UP Sequence Wire Feeder SetupInch Wire Feed Speed Setting Travel ModeChanging Weld Modes Weld Mode Description Mode Select Panel 4 MSP4Table B.1 DescriptionAC Control Start OptionsSetup Mode Options Set TimersSetup END OptionsParameter Units Range Default Value Where is IT SET? Weld Sequence Parameter ListGeneral Setup Mode Options LOCKOUT/SECURITY Infrared IR ControlPanel Procedure Memory VS. User Memory Multi Procedure WeldingMemory Recalling Memory SavingHigh Limit Limit SettingAttribute Accessories General Options AccessoriesMaintenance Safety PrecautionsRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideLINC-NET System Error Codes Your local Lincoln Authorized Field Service FacilityField Service Facility Your local Lincoln AuthorizedContact your local Lincoln Output Problems Troubleshooting Power Feed 10A Controller Dimensionprint M20414Precaucion Warnung