INSTALLATION

A-4

 

 

 

4.Replace the Switch Panel on the POWER FEED™ 10A CONTROLLER with the blank panel included with the pendant box.

5.Connect the Switch Panel to the mating 10-pin con- nector inside the pendant box.

6.Fasten the Switch Panel to the pendant box.

7.Connect the 14-pin/9-pin pendant cable to the mat- ing cable connector on the bottom of the POWER FEED™ 10A CONTROLLER and the mating cable connector on the pendant.

8.The remote pendant is now ready to be used.

Interfacing to the Switch Panel Controls:

The Switch Panel circuits can be accessed on the screwless terminal strip. Easy access to these circuits enables the POWER FEED™ 10A CONTROLLER to interface with custom controls or PLC’s. These circuits must see a contact closure to function properly.

1.Remove all input power to the POWER FEED™ 10A CONTROLLER including any auxiliary power supplies.

2.Remove the fasteners from the Switch Panel and disconnect the Switch Panel from the wire harness. The Switch Panel should be stored in a secure

CAUTION

place in the event that it is needed in the future.

The Switch Panel should not be left in the POWER FEED™ 10A CONTROLLER if the switches are not connected. This could cause a safety concern due to the fact that the switches will not stop the welding sequence, etc.

--------------------------------------------------------------------------------

3.Jumper the wire harness connector (J2) to the mat- ing 10-pin connector (P2P) that is floating inside the control box (See Wiring Diagram).

4.Replace the Switch Panel on the POWER FEED™ 10A CONTROLLER with the blank panel included with the pendant box.

5.Remove the wire duct cover to gain access to the leads on the right side of the terminal strip.

6.Remove the leads going to the Pendant 14-pin con- nector from the right side of terminal strip blocks #39, #40, #41, #42, #43, #44, #45, #46, & #47. (Note – see Auxiliary Input Power Connection Instructions on how to remove/install wires to the screwless terminal strip)

7.Remove one of the plug buttons located on the bot- tom of the POWER FEED™ 10A CONTROLLER control box and install some type of strain relief for the interfacing leads.

8.Connect the interfacing leads to the Switch Panel circuits on the terminal strip (see Wiring Diagram for terminal strip designations). The supply for START, STOP, and INCH UP comes from SWITCH GROUP #1 SUPPLY on block #39. The supply for TRAVEL AUTO, TRAVEL ON, FLUX FILL, and INCH DOWN comes from SWITCH GROUP #2 SUPPLY on block #43.

9.To activate any of the Switch Panel circuits, a con- tact closure must be established between the sup- ply and the particular circuit it is referenced to – for instance, to start the weld sequence, a contact clo- sure must be established momentarily between ter- minal strip blocks #39 (SUPPLY) and #40 (START). See FIGURE A.2.

10.The leads from the 14-pin connector that were removed from the terminal strip can be taped and secured in the wire duct located next to the termi- nal strip.

POWER FEED™ 10A CONTROLLER

Image 11
Contents Power Feed 10A Controller California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents General Information Technical Specifications Power Feed 10A ControllerPower Feed 10A Controller Safety Precaution InstallationConverting Switch Panel to a remote pendant Interfacing to the Power Feed 10A ControllerAuxiliary Input Power Connection Instructions Interfacing to the Switch Panel Controls Figure A.2 Controlling NON-LINCOLN Auxiliary EquipmentStop Input Shutdown InputsPower Feed 10A Controller Control BOX Connection Diagram SystemWelding with Multiple Arcs Remote Sense Lead SpecificationsCommon Welding Abbreviations Design FeaturesOperation Definitions of Welding ModesEquipment Limitations Product DescriptionRecommended Processes Process LimitationsControl BOX With Door Control BOX Without Door Power Feed 10A ControllerLocating Front Panel Controls and INPUT, Ouput Connections LED condition Definition Case Front Controls Case Front Control DescriptionsTravel Mode POWER-UP SequenceWire Feeder Setup Inch Wire Feed Speed SettingDescription Changing Weld Modes Weld Mode DescriptionMode Select Panel 4 MSP4 Table B.1Start Options AC ControlEND Options Setup Mode OptionsSet Timers SetupWeld Sequence Parameter List Parameter Units Range Default Value Where is IT SET?General Setup Mode Options Panel Infrared IR ControlLOCKOUT/SECURITY Memory Saving Procedure Memory VS. User MemoryMulti Procedure Welding Memory RecallingAttribute Limit SettingHigh Limit General Options Accessories AccessoriesPeriodic Maintenance MaintenanceSafety Precautions Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingYour local Lincoln Authorized Field Service Facility LINC-NET System Error CodesYour local Lincoln Authorized Field Service FacilityContact your local Lincoln Output Problems Troubleshooting Power Feed 10A Controller M20414 DimensionprintPrecaucion Warnung