TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
|
|
| ||
|
| |||
Err 006 |
| 1. The wire feeder has not received | ||
|
|
|
| a recognition command from the |
|
|
|
| power source. Verify the power |
|
|
|
| source is operating properly |
|
|
|
| (Status light steady green.) |
|
|
| 2. | Check control cable for loose or |
|
|
|
| broken leads. |
|
|
| 3. | See power source Instruction |
|
|
|
| Manual. |
|
|
|
| |
Err 100 |
| 1. The power source has issued a | ||
|
|
|
| shutdown command. Verify the |
|
|
|
| power source is operating proper- |
|
|
|
| ly. (Status light steady green.) |
|
|
| 2. | Check control cable for loose or |
|
|
|
| broken leads. |
|
|
| 3. | See power source instruction |
|
|
|
| Manual. |
|
|
|
| |
|
| ARCLINK SYSTEM | ERROR CODES | |
Err 31 |
| Primary overcurrent | 1. The power source has exceeded | |
|
|
|
| input current limits. Adjust the |
|
|
|
| welding procedure to reduce the |
|
|
|
| current draw. The welding proce- |
|
|
|
| dure may exceed the capacity of |
|
|
|
| the power source. |
|
|
| 2. | See the power source Instruction |
|
|
|
| Manual. |
|
|
|
| |
Err 32 |
| Capacitor bank "A" under | 1. The power source input power | |
|
| voltage. |
| may be wired incorrectly. Verify |
|
|
|
| the power source reconnect |
|
|
|
| panel wiring matches the input |
|
|
|
| power. |
|
|
| 2. See the power source Instruction | |
|
|
|
| Manual. |
|
|
|
|
|
|
|
|
|
|
If all recommended possible areas of misadjustment have been checked and the problem persists, Contact
your local Lincoln Authorized Field Service Facility.
![]()
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.