Lincoln Electric IM849 manual Infrared IR Control, Lockout/Security, Panel

Page 26

B-11

OPERATION

B-11

 

 

 

P.21 ShutdownStandard

Shutdown2 Select

Press the right Mode Select Button.

Turn the Knob to toggle between Standard Shutdown or Output Lockout.

This option allows the user to use the shutdown 2 input on the control box to lock the welding output in the OFF state, but still allow cold feeding of the wire.

Standard Shutdown = Default behavior, normal shut- down mode prevents cold feed of wire.

Output Lockout = Allows cold feed of wire and pre- vents the activation of welding output.

Pressing the left Mode Select Panel Pushbutton will exit the parameter setting section, returning to the previous section. Continuing to press the left Mode Select Panel Pushbutton will return to the Setup Mode user preferences and welding parameters list.

Diagnostic tools SHOW TEST MODES and VIEW DIAGS can be accessed in the Mode Select Panel Setup Mode also, but these tools should only be accessed by properly trained personnel.

INFRARED (IR) CONTROL

The Mode Select Panel interface includes an infrared transceiver. This allows wireless machine configura- tion using a Palm OS based handheld computer. A proprietary Palm OS application, ALPalm, has been developed for this purpose.

LOCKOUT/SECURITY

The Power Feed 10A can be optionally configured to prevent the operator from changing selected Power Feed 10A panel controls. By default, the welder will be able to change the weld mode, all relevant wave controls and all relevant start and end options.

Here is a list of Lockout levels:

PANEL

LOCKOUT LEVEL

All Mode Select options unlocked (default).

All Mode Select options locked.

START OPTIONS and END OPTIONS locked.

WELD MODE selection locked, only wave

controls are unlocked (useful when Memory) Mode Select Panel is used to recall weld modes.

AC CONTROL locked.

START OPTIONS, END OPTIONS, and wave options locked.

START OPTIONS, END OPTIONS, and

WELD MODE locked.

All memories enabled (default).

All memories disabled.

Memories 2-6 disabled.

Memory Panel Memories 3-6 disabled.

Memories 4-6 disabled.

Memories 5-6 disabled.

Memory 6 disabled.

Both knobs unlocked (default).

Both knobs locked.

Encoder Panel

Right knob locked.

Left knob locked.

Note that when an option is locked, its value can still be monitored. For example, if start and end options are locked, the welder can still press the right Mode Select Panel Pushbutton and see the value set for Start Time. If the welder attempts to change its value, a message will briefly appear on the Mode Select Panel indicating "MSP Option is LOCKED!".

Presently, lockout features are only available through a PC application or the IR Port.

POWER FEED™ 10A CONTROLLER

Image 26
Contents Power Feed 10A Controller Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents General Information Technical Specifications Power Feed 10A ControllerPower Feed 10A Controller Installation Safety PrecautionConverting Switch Panel to a remote pendant Interfacing to the Power Feed 10A ControllerAuxiliary Input Power Connection Instructions Interfacing to the Switch Panel Controls Controlling NON-LINCOLN Auxiliary Equipment Figure A.2Shutdown Inputs Stop InputConnection Diagram System Power Feed 10A Controller Control BOXRemote Sense Lead Specifications Welding with Multiple ArcsDefinitions of Welding Modes Design FeaturesOperation Common Welding AbbreviationsProcess Limitations Product DescriptionRecommended Processes Equipment LimitationsControl BOX With Door Control BOX Without Door Power Feed 10A ControllerLocating Front Panel Controls and INPUT, Ouput Connections Case Front Controls Case Front Control Descriptions LED condition DefinitionInch Wire Feed Speed Setting POWER-UP SequenceWire Feeder Setup Travel ModeTable B.1 Changing Weld Modes Weld Mode DescriptionMode Select Panel 4 MSP4 DescriptionAC Control Start OptionsSetup Setup Mode OptionsSet Timers END OptionsParameter Units Range Default Value Where is IT SET? Weld Sequence Parameter ListGeneral Setup Mode Options Panel Infrared IR ControlLOCKOUT/SECURITY Memory Recalling Procedure Memory VS. User MemoryMulti Procedure Welding Memory SavingAttribute Limit SettingHigh Limit Accessories General Options AccessoriesRoutine Maintenance MaintenanceSafety Precautions Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideLINC-NET System Error Codes Your local Lincoln Authorized Field Service FacilityField Service Facility Your local Lincoln AuthorizedContact your local Lincoln Output Problems Troubleshooting Power Feed 10A Controller Dimensionprint M20414Precaucion Warnung