Lincoln Electric IM849 manual Weld Sequence Parameter List

Page 24

B-9

 

 

OPERATION

B-9

 

 

 

 

 

 

 

 

WELD SEQUENCE PARAMETER LIST

 

 

 

 

 

 

PARAMETER

UNITS

RANGE

DEFAULT VALUE

WHERE IS IT SET?

 

 

 

 

 

Arc Delay Time

seconds

0-5.0

OFF

MSP4 - START OPTIONS

 

 

 

 

 

Strike Fault Time

seconds

0-10.0

OFF

MSP4- SETUP Menu

 

 

 

 

 

 

 

Strike WFS

IPM

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Strike Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

 

 

Restrike Time

seconds

0-10.0

OFF

MSP4 - SETUP Menu

 

 

 

 

 

Start WFS/Amps

IPM/amperes

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Start Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

 

 

Start Time

seconds

0-0.5

0.1

MSP4 - START OPTIONS

 

 

 

 

 

Start Arc Force

amperes

from weld table*

weld mode dependant

MSP4 - SETUP Menu

 

 

 

 

 

 

 

Upslope Time

seconds

0-10.0

OFF

MSP4 - SETUP Menu

 

 

 

 

 

Weld WFS/Amps

IPM/amperes

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Weld Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

Weld Arc Force

amperes

from weld table*

weld mode dependant

MSP4 - SETUP Menu

 

 

 

 

 

Frequency (AC)

hertz

10-100

weld mode dependant

AC CONTROL

 

 

 

 

 

 

 

Balance (AC)

percent

25-75

weld mode dependant

AC CONTROL

 

 

 

 

 

 

 

Offset (AC)

percent

-50.0 - +50.0

0.0

AC CONTROL

 

 

 

 

 

Arc 2 Phase (if applicable)

degrees

0-359

90

AC CONTROL

 

 

 

 

 

Arc 2 Balance (if applicable)

percent

25-75

50

AC CONTROL

 

 

 

 

 

Arc 3 Phase (if applicable)

degrees

0-359

180

AC CONTROL

 

 

 

 

 

Arc 3 Balance (if applicable)

percent

25-75

50

AC CONTROL

 

 

 

 

 

Arc 4 Phase (if applicable)

degrees

0-359

270

AC CONTROL

 

 

 

 

 

Arc 4 Balance (if applicable)

percent

25-75

50

AC CONTROL

 

 

 

 

 

Downslope Time

seconds

0-10.0

OFF

MSP4 - SETUP Menu

 

 

 

 

 

Crater WFS/Amps

IPM/amperes

from weld table*

weld mode dependant

Left Dual Display

 

 

 

 

 

 

 

Crater Volts

volts

from weld table*

weld mode dependant

Right Dual Display

 

 

 

 

 

 

 

Crater Time

seconds

0-10.0

OFF

END OPTIONS

 

 

 

 

 

Crater Arc Force

amperes

from weld table*

weld mode dependant

MSP4 - SETUP Menu

 

 

 

 

 

Burnback Time

seconds

0-2.0

0.2

END OPTIONS

 

 

 

 

 

 

* Range depends on the Machine Power Source, Literature and Tables supplied with each unit.

POWER FEED™ 10A CONTROLLER

Image 24
Contents Power Feed 10A Controller Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Technical Specifications Power Feed 10A Controller Power Feed 10A ControllerGeneral Information Installation Safety PrecautionInterfacing to the Power Feed 10A Controller Auxiliary Input Power Connection InstructionsConverting Switch Panel to a remote pendant Interfacing to the Switch Panel Controls Controlling NON-LINCOLN Auxiliary Equipment Figure A.2Shutdown Inputs Stop InputConnection Diagram System Power Feed 10A Controller Control BOXRemote Sense Lead Specifications Welding with Multiple ArcsDesign Features OperationDefinitions of Welding Modes Common Welding AbbreviationsProduct Description Recommended ProcessesProcess Limitations Equipment LimitationsControl BOX Without Door Power Feed 10A Controller Locating Front Panel Controls and INPUT, Ouput ConnectionsControl BOX With Door Case Front Controls Case Front Control Descriptions LED condition DefinitionPOWER-UP Sequence Wire Feeder SetupInch Wire Feed Speed Setting Travel ModeChanging Weld Modes Weld Mode Description Mode Select Panel 4 MSP4Table B.1 DescriptionAC Control Start OptionsSetup Mode Options Set TimersSetup END OptionsParameter Units Range Default Value Where is IT SET? Weld Sequence Parameter ListGeneral Setup Mode Options Infrared IR Control LOCKOUT/SECURITYPanel Procedure Memory VS. User Memory Multi Procedure WeldingMemory Recalling Memory SavingLimit Setting High LimitAttribute Accessories General Options AccessoriesMaintenance Safety PrecautionsRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideLINC-NET System Error Codes Your local Lincoln Authorized Field Service FacilityField Service Facility Your local Lincoln AuthorizedContact your local Lincoln Output Problems Troubleshooting Power Feed 10A Controller Dimensionprint M20414Precaucion Warnung