Lincoln Electric IM730 manual Connection of Lincoln Electric Wire Feeders

Page 15

A-7

INSTALLATION

A-7

 

 

 

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

Connection of LN-7 or LN-8 to the RANGER 305D

Shut the welder off.

Connect the LN-7 or LN-8 per instructions on the appropriate connection diagram in Section F.

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode being used.

Set the "MODE" switch to the "CV WIRE " position.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "WELD TERMINALS" switch to the "REMOTELY CONTROLLED" position.

Set the "IDLE" switch to the "HIGH" position.

Connection of LN-742, Spool Gun(K487-25SG)and Cobramatic to RANGER 305D

Shut the welder off.

Connect per instructions on the appropriate connec- tion diagram in Section F.

Connection of LN-15 to the Ranger 305D

These connections instructions apply to both the LN-

15Across-The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Across-The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the MODE switch to the "CV-WIRE " position.

Across-The-Arc Model:

Set the "WELD TERMINALS" switch to "WELD TER-

MINALS ON"

Control Cable Model:

Set the "WELD TERMINALS" switch to "REMOTELY CONTROLLED"

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "High" position

Connection of an LN-23P Wire Feeder to the RANGER 305D

Shut the welder off.

Connect the LN-23P as per instructions on the appropriate connection diagram in Section F. (NOTE): When connecting an LN-23P to the RANGER 305D, a K350-1 adapter kit must be used.

Set the "VOLTMETER" switch to "-".

Set the "MODE" switch to "CV WIRE " position.

Set the "WELD TERMINALS" switch to "REMOTELY CONTROLLED".

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "AUTO" position. When not welding, the RANGER 305D engine will be at the low idle speed. If you are using an LN-23P with the K350-1 adapter kit, the electrode is not energized until the gun trigger is closed. When the gun trigger is closed, the current sensing circuit will cause the RANGER 305D engine to go to the high idle speed, the wire will begin to feed and the welding process can be started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

RANGER 305D

Image 15
Contents Ranger 305 D Safety Electric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents P417 Section DSection E Section FRanger 305D Height Width Depth WeightAIR Cleaner Engine Idler Muffler Engine Protection Lubrication Emissions Fuel System GovernorLocation and Ventilation Safety PrecautionsOIL PRE-OPERATION Engine ServiceBattery Connection Vehicle MountingElectrical Connections Total Combined Length of Electrode and Work Cables Auxiliary Power ReceptaclesStandby Power Connections Cable InstallationConnection of Ranger 305D to Premises Wiring Connection of LN-15 to the Ranger 305D Connection of Lincoln Electric Wire FeedersConnection of an LN-23P Wire Feeder to the Ranger 305D Connection of LN-7 or LN-8 to the Ranger 305DConnection of Prince XL Spool GUN to the Ranger 305D Terminals onEngine Operation Safety PrecautionsFor Auxiliary Power General DescriptionDigital Output Meters Weld Mode Selector SwitchFigure B.2 Wire Feeder Voltmeter SwitchTable B.1 Starting the EngineStopping the Engine Typical Ranger 305D Fuel ConsumptionTIG Welding Welder OperationTypical Current Ranges 1 for Tungsten ELECTRODES2 Duty CycleWire WELDING-CV ARC GougingTable B.3 Ranger 305D Extension Cord Length Recommendations Auxiliary PowerTIG Options Field Installed Options / AccessoriesKubota D722 Diesel Engine Engine Maintenance Components Kubota D722 Diesel EngineOil Filter Change AIR CleanerEngine Oil Refill capacities Without oil filter replacement Engine Oil ChangeService Instructions & Installation Tips Cooling System Tightening the FAN BeltBleeding the Fuel System Engine Adjustment Battery MaintenanceServicing Optional Spark Arrestor Welder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingAuthorized Field Service Facility Your local LincolnContact your local Lincoln Welding without a control cable Functioning properly / linkage Faulty control cable. Repair or Process being used. For exam Diagrams Diagrams Diagrams Diagrams Diagrams S24787-6 Engine Welders /LN-8 Connection DiagramDiagrams Diagrams Diagrams Diagrams Diagrams Ranger 305D- Kubota Wiring Diagram Dimension Print Ranger 305D Ranger 305D Ranger 305D Precaucion Warnung