WELDING CONTROLS (Figure B.1)
1.OUTPUT CONTROL: The OUTPUT dial is used to preset the output voltage or current as dis- played on the digital meters for the four welding modes. When in the CC-STICK, DOWNHILL PIPE or CV-WIRE modes and when a remote control is con- nected to the 6-Pin or 14-Pin Connector, the auto- sensing circuit automatically switches the OUTPUT CONTROL from control at the welder to the remote control.
In the CV-WIRE mode, when the wire feeder control cable is connected to the 14-Pin Connector, the auto- sensing circuit automatically makes OUTPUT CON- TROL inactive and the wire feeder voltage control active.
When in the TOUCH START TIG mode and when a Amptrol is connected to the 6-Pin Connector, the OUTPUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.
2. DIGITAL OUTPUT METERS
The digital meters allow the output voltage (CV-WIRE mode) or current (CC-STICK, PIPE and TIG modes) to be set prior to welding using the OUTPUT control dial. During welding, the meter display the actual out- put voltage (VOLTS) and current (AMPS). A memory feature holds the display of both meters on for seven seconds after welding is stopped. This allows the operator to read the actual current and voltage just prior to when welding was ceased.
While the display is being held the left-most decimal point in each display will be flashing. The accuracy of the meters is +/- 3%.
3. WELD MODE SELECTOR SWITCH:
(Provides four selectable welding modes)
CV-WIRE DOWNHILL PIPE CC-STICK TOUCH START TIG