Lincoln Electric SVM 119-A service manual Cylinder may explode if damaged

Page 3

ii

SAFETY

ii

 

 

Return to Master TOC

Return to Master TOC

Return to Master TOC

WELDING SPARKS can cause fire or explosion.

4.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot

materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

4.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

4.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

4.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

4.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

4.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

4.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.

4.h. Also see item 7c.

CYLINDER may explode if damaged.

5.a. Use only compressed gas cylinders

containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

5.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

5.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

5.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

5.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

5.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

5.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

6.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

6.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

6.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Return to Master TOC

Feb. ‘95

WIRE-MATIC 255

Image 3
Contents Safety Depends on You WIRE-MATICFumes and Gases can be dangerous SafetyElectric Shock can kill ARC Rays can burnWelding Sparks can cause fire or explosion Cylinder may explode if damagedElectric and MAG- Netic Fields May be dangerousIii Sûreté Pour Soudage a L’Arc Précautions DE SûretéWIRE-MATIC Table of Contents Table of Contents Table of Contents Installation Section InstallationTechnical Specifications Wire-Matic-255 Stacking Safety PrecautionsSelect Proper Location Input ConnectionsFuse and Wire Sizes Connect Shielding GAS Figure A.4 Input Gas Supply Connections Reconnect ProcedureFigure A.5 Reconnect Diagram For 208/230/1/60 Machines Connections Connect Output ComponentsGUN and Cable Installation Wire Size Conversion PartsWIRE-MATIC Operation Table of Contents Operation SectionSafety Instructions General DescriptionWELDING, Cutting Recommended Processes and Equipment Design Features AdvantagesMachine Capability LimitationsDuty Cycle Amps Volts Figure B.1 Operator Controls Controls and SettingsFigure B.2 Wire Reel Loading Using the Wire Drive RollFeeding Electrode Operating Steps Setting Idle Roll PressureMaking a Weld WIRE-MATIC Table of Contents Accessories Section AccessoriesOPTIONS/ACCESSORIES Magnum GUN Connection KIT Optional K466-6K672-1 Spool GUN Adapter KIT Making a Weld with the Spool GUN Adapter K672-1 Installed Timer KIT Installation Optional K585-1 Timer KIT K585-1K363P READI-REEL Adapter Drive Roll Kits64 1.2mm Aluminum Feeding KIT K673-1 K468 8 Spool AdapterDual Cylinder Mounting KIT K671-1 Table of Contents Maintenance Section MaintenancePerform the following daily Routine and Periodic MaintenanceMaintenance GUN Tubes and Nozzles Cable CleaningContact TIP and GAS Nozzle Installation Drive Rolls and Guide TubesFigure D.2 Liner maintenance Liner Removal ReplacementTo open up the handle GUN Handle DisassemblyDescription English Size Metric Size WIRE-MATIC Theory of Operation Table of Contents Theory of Operation SectionTransformer Input Line Voltage and MainFeedback Control Output RectificationFigure E.4 Constant Voltage Output Constant Voltage OutputFeedback Wire Drive MotorThermal Protection Figure E.6 SCR Operation SCR OperationWIRE-MATIC Table of Contents Troubleshooting & Repair Section Troubleshooting & RepairRecommended Course of Action HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Electric Shock can killBoard can be dam- aged by static electricity Main Transformer Rectifier Assembly Test To Section TOC SCR Rectifier Perform the Wire Drive Motor Trolyte in these capacitors is Liquid elecPerform the Output Rectifier Main Transformer Test Test DescriptionMaterials Needed ON/OFF Power Switch will be hot during these tests Main Transformer Test Test ProcedureLead Plug Location Static SCR Rectifier Assembly Test Leads Figure F.4 SCR 1 Test Points Active SCR Rectifier Assembly Test Leads SCR connections Figure F.7 SCR Tester CircuitWire Drive Motor and Tachometer Feedback Test Wire Drive Motor and Tachometer Feedback Test Test Procedure Test for Feedback Voltage to the Control Board Test for Supply Voltage to TachometerNormal Open Circuit Voltage Waveform Scope SettingsTypical Output Voltage Waveform Machine Loaded Machine Loaded to 250 Amps AT 26 VDC Scope SettingsMachine Loaded to 220 Amps AT 22 VDC Scope Settings Troubleshooting & Repair Typical SCR Gate Voltage Waveform Removal and Replacement Procedure Control PC Board Removal and ReplacementRemoval and REPLACE- Ment Procedure Wire Drive Assembly Removal and Replacement Figure F.11 Wire Drive Assembly Removal ProcedureSCR Output Rectifier Removal & Replacement Disconnection Heat Sink Lead Right side heat sink See Figure F.14Capacitor Bank Removal and Replacement Components Bank Removal ReplacementMain Transformer Removal and Replacement Power Switch FAN Motor and FAN Removal and Replacement Figure F.16 Fan Motor and Fan Removal Components FAN Motor and FAN Removal and Replacement ProcedureTroubleshooting & Repair 230/60 375 Wire Speed RangeOpen Circuit Voltage Input Volts/HertzWIRE-MATIC Table of Contents Electrical Diagrams Section WIRE-MATIC Wiring Diagram 208/230 Code Electrical DiagramsWiring Diagram 230/460/575 Code Wire Matic 255 230 / 460Control PC Board G2803 Schematic Control PC Board G2803 Layout Wirematic 255 Control