OPERATION | ||
|
|
|
STOPPING THE ENGINE
Remove all welding and auxiliary power loads and allow the engine to run at low idle speed for a few minutes to cool the engine.
Stop the engine by placing the “Engine” switch in the “STOP” position.
A fuel shut off valve is not required on the
TABLE B.1
TYPICAL GX-271 FUEL CONSUMPTION
| Honda Engine | ||
|
|
| |
Low Idle - No Load | .35 US gallons/hour | .40 US gallons/hour | |
2400 RPM | (.29 Imp. gal./hr., 1.31 liters/hour) | (.34 Imp. gal./hr., 1.53 liters/hour) | |
|
|
| |
High Idle - No Load | .76 US gallons/hour | .87 US gallons/hour | |
3700 RPM | (.63 Imp. gal./hr., 2.86 liters/hour) | (.73 Imp. gal./hr., 3.30 liters/hour) | |
|
|
| |
210 Amps @ 25 Volts | 1.21 US gallons/hour | 1.27 US gallons/hour | |
DC Weld Output | (1.01 Imp. gal./hr., | 4.57 liters/hour) | (1.06 Imp. gal./hr., 4.82 liters/hour) |
|
|
| |
250 Amps @ 25 Volts | 1.40 US gallons/hour | 1.37 US gallons/hour | |
DC Weld Output | (1.17 Imp. gal./hr., | 5.30 liters/hour) | (1.14 Imp. gal./hr., 5.17 liters/hour) |
|
|
| |
275 Amps @ 25 Volts | 1.53 US gallons/hour | 1.44 US gallons/hour | |
DC Weld Output | (1.27 Imp. gal./hr., | 5.79 liters/hour) | (1.20 Imp. gal./hr., 5.45 liters/hour) |
|
|
| |
275 Amps @ 28 Volts | 1.67 US gallons/hour | 1.53 US gallons/hour | |
DC Weld Output | (1.39 Imp. gal./hr., | 6.32 liters/hour) | (1.28 Imp. gal./hr., 5.80 liters/hour) |
|
|
| |
8,000 kVA | 1.56 US gallons/hour | 1.47 US gallons/hour | |
Auxiliary Power | (1.30 Imp. gal./hr., | 5.89 liters/hour) | (1.22 Imp. gal./hr., 5.55 liters/hour) |
|
|
|
|
GX 271 Chopper