Lincoln Electric 205-TAC/DCTIG manual Installation, Operating Temperature Range

Page 10

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - V205-T DC TIG K2629-1 (Code Number 11426) V205-T AC/DC TIG K1855-4 (Code Number 11430)

INPUT - SINGLE PHASE ONLY

Input Voltages * / 50 /60 Hz.

115

230

Max. Input Current

34A at Rated Output

30A at Rated Output

 

 

RATED OUTPUT

 

 

 

Duty Cycle

Output Amps

Volts at Rated Amperes

Input Amps

 

(115V) 35%

(Stick) 110

24.4V

34A

 

60%

90

23.6V

28A

 

100%

70

22.8V

20A

 

 

 

 

 

 

 

(115V) 40%

(TIG) 150

16V

34A

 

60%

120

14.8V

25A

 

100%

100

14V

20A

 

 

 

 

 

 

 

(230V) 35%

(Stick) 180

27.2V

30A

 

60%

150

26V

23A

 

100%

130

25.2V

19A

 

(230V) 40%

(TIG) 200

18V

30A

 

60%

170

16V

18A

 

100%

140

15.6V

15A

 

 

 

 

 

 

 

 

 

 

 

 

Output Current

Range

6-200 Amps

OUTPUT

Maximum Open

Circuit Voltage

54 Volts Max.

Type of Output

DC (K2629-1) AC/DC (K1855-4)

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

 

INPUT

TYPE S, SO ST, STO, OR EXTRA

TIME-DELAY CIRCUIT BREAKER

VOLTAGE / FREQUENCY

HARD USAGE INPUT CORD AWG

OR FUSE SIZE (AMPS)

 

(HZ)

 

 

 

 

 

 

 

 

 

 

 

115/50/60

#12

 

30A

 

230/50/60

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

Height

 

Width

 

Depth

 

Weight

15 in.

 

8.5 in.

 

19 in.

 

Approx. 38 lbs.

381 mm

 

216 mm

 

483 mm

 

17 kgs.

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-50°C to +85°C

*Note: Refer to RECONNECT PROCEDURE (Table A.1) for Input

Voltage Operating Range.

V205-T DC & V205-T AC/DC TIG

Image 10
Contents Invertec V205-T DC & V205-T AC/DC TIG April Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcV205-T DC & V205-T AC/DC TIG Safety Thank You Table of Contents Operating Temperature Range InstallationStorage Temperature Range Tilting Select Suitable LocationStacking Environmental AreaTable A.1 Reconnect ProcedureInput Connections Nominal Range115V Input Attachment Plug Installation230V Input Engine Driven GeneratorOutput Connection for Stick Welding Figure A.2 Output and GAS Connection for TIG Welding Figure A.1Work Cable Connection Remote Control Connection Shielding GAS ConnectionGeneral Description Safety InstructionsOperation Welding CapabilityRear Control Panel Figure B.1 Figure B.1Controls and Settings Figure B.2Step Diagram TIG DC SET UP Menu Indicator Parameter DefaultOutput Limitations Welding PolarityPulsed TIG Alternating Current AC/DC model onlyTips for AC TIG Welding Steel TIG WeldingCopper TIG Welding Filler MaterialTips for Improved TIG Starting Protective GASAC TIG Welding Quick Start UP AC TIGDC TIG Welding Quick Start UP Compatible Equipment AccessoriesOptional Accessories Cable PlugsInput Filter Capacitor Discharge Procedure MaintenanceSafety Precautions Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Field Service Facility Problems TIG WeldingYour local Lincoln Authorized Failures DisplayWiring Diagrams V205-T DC Wiring Diagram forV205-T AC/DC Wiring Diagram for V205-T DC & V205-T AC/DC TIG V205-T DC & V205-T AC/DC TIG Precaucion Warnung