INSTALLATION |
TECHNICAL SPECIFICATIONS -
INPUT - SINGLE PHASE ONLY
Input Voltages * / 50 /60 Hz.
115
230
Max. Input Current
34A at Rated Output
30A at Rated Output
|
| RATED OUTPUT |
|
| |
| Duty Cycle | Output Amps | Volts at Rated Amperes | Input Amps | |
| (115V) 35% | (Stick) 110 | 24.4V | 34A | |
| 60% | 90 | 23.6V | 28A | |
| 100% | 70 | 22.8V | 20A | |
|
|
|
|
|
|
| (115V) 40% | (TIG) 150 | 16V | 34A | |
| 60% | 120 | 14.8V | 25A | |
| 100% | 100 | 14V | 20A | |
|
|
|
|
|
|
| (230V) 35% | (Stick) 180 | 27.2V | 30A | |
| 60% | 150 | 26V | 23A | |
| 100% | 130 | 25.2V | 19A | |
| (230V) 40% | (TIG) 200 | 18V | 30A | |
| 60% | 170 | 16V | 18A | |
| 100% | 140 | 15.6V | 15A | |
|
|
|
|
|
|
|
|
|
|
|
|
Output Current
Range
OUTPUT
Maximum Open
Circuit Voltage
54 Volts Max.
Type of Output
DC
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
| INPUT | TYPE S, SO ST, STO, OR EXTRA | ||||
VOLTAGE / FREQUENCY | HARD USAGE INPUT CORD AWG | OR FUSE SIZE (AMPS) | ||||
| (HZ) |
|
|
|
| |
|
|
|
|
|
| |
| 115/50/60 | #12 |
| 30A | ||
| 230/50/60 |
| ||||
|
|
|
|
|
|
|
|
|
|
| PHYSICAL DIMENSIONS |
| |
Height |
| Width |
| Depth |
| Weight |
15 in. |
| 8.5 in. |
| 19 in. |
| Approx. 38 lbs. |
381 mm |
| 216 mm |
| 483 mm |
| 17 kgs. |
|
|
|
|
|
|
|
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
*Note: Refer to RECONNECT PROCEDURE (Table A.1) for Input