Lincoln Electric 205-TAC/DCTIG Select Suitable Location, Stacking, Tilting, Environmental Area

Page 11

A-2

INSTALLATION

A-2

 

 

 

Read entire installation section before starting installation.

Safety Precautions

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should per- form this installation.

Turn the input power OFF and unplug the machine from the recep- tacle before working on this equip- ment. Allow machine to sit for 5 min- utes minimum to allow the power capacitors to discharge before working inside this equipment.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

Always connect the V205-T to a power supply grounded according to the National Electrical Code and local codes.

------------------------------------------------------------

SELECT SUITABLE LOCATION

The Invertec will operate in harsh environments. Even so, it is important that simple preventative measures are followed in order to assure long life and reliable operation.

The machine must be located where there is free cir- culation of clean air such that air movement in the back and out the front will not be restricted.

Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.

STACKING

The Invertec V205-T DC & V205-T AC/DC can not be stacked.

TILTING

Place the machine directly on a secure, level surface. The machine may topple over if this procedure is not followed.

ENVIRONMENTAL AREA

Keep the machine dry. Do not place it on wet ground or in puddles.

MACHINE GROUNDING AND HIGH FRE- QUENCY INTERFERENCE PROTECTION

The Capacitor Discharge Circuit used in the high fre- quency generator, may cause many radio, TV and electronic equipment interference problems. These problems may be the result of radiated interference. Proper grounding methods can reduce or eliminate radiated interference.

The Invertec V205-T DC & V205-T AC/DC have been field tested under recommended installation condi- tions. It complies with FCC allowable limits for radia- tion.

Radiated interference can develop in the following four ways:

1.Direct interference radiated from the welder.

2.Direct interference radiated from the welding leads.

3.Direct interference radiated from feedback into the power lines.

4.Interference from re-radiation of “pickup” by ungrounded metallic objects.

Keeping these contributing factors in mind, installing equipment per the following instructions should mini- mize problems.

1.Keep the welder power supply lines as short as possible and enclose as much of them as possible in rigid metallic conduit or equivalent shielding for a distance of 50 feet (15.2m). There should be good electrical contact between this conduit and the welder case ground. Both ends of the conduit should be connected to a driven ground and the entire length should be continuous.

2.Keep the work and electrode leads as short as possible and as close together as possible. Lengths should not exceed 25 ft (7.6m).

V205-T DC & V205-T AC/DC TIG

Image 11
Contents Invertec V205-T DC & V205-T AC/DC TIG April California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéV205-T DC & V205-T AC/DC TIG Safety Thank You Table of Contents Storage Temperature Range InstallationOperating Temperature Range Environmental Area Select Suitable LocationStacking TiltingNominal Range Reconnect ProcedureInput Connections Table A.1Engine Driven Generator Attachment Plug Installation230V Input 115V InputWork Cable Connection Output and GAS Connection for TIG Welding Figure A.1Output Connection for Stick Welding Figure A.2 Shielding GAS Connection Remote Control ConnectionWelding Capability Safety InstructionsOperation General DescriptionFigure B.1 Rear Control Panel Figure B.1Figure B.2 Controls and SettingsStep Diagram TIG DC Indicator Parameter Default SET UP MenuWelding Polarity Output LimitationsAlternating Current AC/DC model only Pulsed TIGFiller Material Steel TIG WeldingCopper TIG Welding Tips for AC TIG WeldingProtective GAS Tips for Improved TIG StartingAC TIG AC TIG Welding Quick Start UPDC TIG Welding Quick Start UP Cable Plugs AccessoriesOptional Accessories Compatible EquipmentRoutine Maintenance MaintenanceSafety Precautions Input Filter Capacitor Discharge ProcedureHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Your local Lincoln Authorized Problems TIG WeldingField Service Facility Display FailuresV205-T DC Wiring Diagram for Wiring DiagramsV205-T AC/DC Wiring Diagram for V205-T DC & V205-T AC/DC TIG V205-T DC & V205-T AC/DC TIG Precaucion Warnung